SPECIFICATIONS

CGN18RA

CGN30D

BTU (Variable)

6,600/12,000/18,000

6,600/18,000/30,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

26 x 20.5 x 9.625

26 x 27.75 x 9.625

Weight (pounds)

 

 

Heater

22

30

Shipping

27

36

SERVICE

When gas pressure is too low

• pilot will not stay lit

HINTS

• burner(s) will have delayed ignition

 

• heater will not produce specified heat

 

When gas quality is bad

 

• pilot will not stay lit

 

• burner(s) will produce flames and soot

 

• heater will backfire when lit

 

You may feel your gas pressure is too low or gas quality is bad. If so, contact your

 

local natural gas supplier.

REPLACEMENT

Note: Use only original replacement parts. This will protect your warranty coverage

PARTS

for parts replaced under warranty.

Parts Under Warranty

 

Contact authorized dealers of this product. If they can’t supply original replacement

 

part(s), either contact your nearest Parts Central (see page 27) or call DESA

 

International’s Technical Service Department at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

model number of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 27) or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

26

101826

Image 26
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Providing Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation Air From Inside Building AIR forVentilation AIR Appliances in both spacesVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Installing To WallInstallation Items Locating HeaterInstalling to Wall Removing Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply CGN30DConnections Pressure Testing GAS Supply Piping SystemChecking GAS Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotTo Select Heating Level Shutting Off Heater Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off Burner Only pilot stays litGRH/OV 019A Trouble Shooting CleaningMaintenance ODS/PILOT and Burner OrificeSee Cleaning TROUBLE- ShootingSee Cleaning and Main Service TechnicalParts Not Under Warranty Replacement PartsParts Under Warranty HintsFAN Kits GA3100, GA3100A, and GA3200TA AccessoriesCentrals Valve GA5010Illustrated Parts Breakdown Model CGN18RAParts List KEY Part Number Description QTYModel CGN30D Control Position Label Hardware Assembly Warranty Information Keep this Warranty

CGN30D, CGN18RA specifications

Desa CGN18RA and CGN30D are two advanced space heaters designed for both residential and commercial use. These models are well-regarded for their innovative features, technologies, and exceptional performance, making them suitable choices for various heating needs, particularly in larger spaces.

The CGN18RA is equipped with several key features that enhance its functionality. It boasts a reliable heat output of approximately 18,000 BTUs, ensuring effective warmth during cold months. This model utilizes infrared technology, which enables it to heat objects and people directly rather than just the air. This not only makes the heating experience more comfortable but also reduces energy consumption. Furthermore, the CGN18RA is designed with an adjustable thermostat to provide precise temperature control, allowing users to set their desired warmth levels easily.

On the other hand, the CGN30D offers a more robust heating solution with an output of up to 30,000 BTUs. This model is particularly suited for larger spaces, effectively warming garages, workshops, or open-plan living areas. Like the CGN18RA, the CGN30D utilizes direct infrared heating technology, ensuring efficient and consistent temperatures are maintained. Users appreciate the dual-fuel capability of the CGN30D, allowing it to operate on both natural gas and propane, which adds to its versatility and convenience.

Both models prioritize safety, featuring built-in mechanisms such as tip-over shut-off systems and automatic shut-off valves to prevent potential hazards. Furthermore, the units are constructed with durable materials that withstand regular use while maintaining sleek designs. Portability is another advantage, with easy-to-move structures allowing users to reposition heaters according to their heating requirements.

In summary, Desa CGN18RA and CGN30D are impressive space heaters characterized by their powerful heating capabilities, energy efficiency, and user-friendly features. Their advanced technology, safety mechanisms, and versatility in fuel options make them outstanding choices for anyone looking to maintain a comfortable environment, whether at home or in a commercial space. With these models, users can enjoy reliable warmth and comfort during the colder months.