Desa CGN18RA, CGN30D installation manual Parts List, KEY Part Number Description QTY

Page 29

PARTS LIST

Model CGN18RA

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

098304-01

Screw, #10 x 3/8"

2

2

098742-03

Front Panel

1

3

098238-06

Grill Guard

1

4

098342-01

Clip-Grill Guard

2

5

098198-03

Apron

1

6

M11084-26

Screw, #10 x 3/8"

9

7

098462-01

Control Rod Assembly

1

8

098457-01

Reflector Assembly

1

9

098867-05

Regulator

1

10

M11084-38

Screw, #8 x 3/8"

2

11

098455-02

Cabinet Assembly

1

12

098324-01

Control Knob

1

13

See Detail

Burner Assembly

1

13-1

099218-01

Burner

1

13-2

098508-01

Valve Retainer Nut

1

13-3

099056-03

Injector

3

13-4

099048-01

Tubing-Valve to plaque A

1

13-5

099049-01

Tubing-Valve to plaque B

1

13-6

099050-01

Tubing-Valve to plaque C

1

13-7

099057-01

Pressure Tap Fitting

1

13-8

098932-06

Control Valve

1

13-9

099045-01

Pilot Tubing-Valve to regulator

1

13-10

099051-01

Inlet Tubing

1

13-11

099059-01

ODS/Pilot

1

13-12

M11084-37

Screw, #8 x 1/4"

3

13-13

099046-02

Pilot Tubing-Regulator to pilot

1

13-14

099918-01

Pilot Regulator

1

13-15

M11084-26

Screw, #10 x 3/8"

2

13-16

098593-01

Thermocouple

1

13-17

098594-01

Ignitor Electrode

1

14

099066-01

Mounting Bracket

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

098465-01 Control Position Label

100642-01 Assembly, Hardware

1

1

101826

29

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Providing Adequate Ventilation AIR for CombustionVentilation Determining if You Have a Confined or Unconfined Space AIR for Combustion and VentilationDetermining AIR Flow for Heater Location Ventilation AIR AIR forVentilation Air From Inside Building Appliances in both spacesVentilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterInstalling to Wall Mounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsCGN30D Connecting to GAS SupplyChecking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsWhat to do if YOU Smell GAS HeaterPilot Operating HeaterTo Select Heating Level Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litGRH/OV 019A Maintenance CleaningTrouble Shooting ODS/PILOT and Burner OrificeTROUBLE- Shooting See CleaningSee Cleaning and Main Technical ServiceParts Under Warranty Replacement PartsParts Not Under Warranty HintsCentrals AccessoriesFAN Kits GA3100, GA3100A, and GA3200TA Valve GA5010Model CGN18RA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGN30D Control Position Label Hardware Assembly Keep this Warranty Warranty Information

CGN30D, CGN18RA specifications

Desa CGN18RA and CGN30D are two advanced space heaters designed for both residential and commercial use. These models are well-regarded for their innovative features, technologies, and exceptional performance, making them suitable choices for various heating needs, particularly in larger spaces.

The CGN18RA is equipped with several key features that enhance its functionality. It boasts a reliable heat output of approximately 18,000 BTUs, ensuring effective warmth during cold months. This model utilizes infrared technology, which enables it to heat objects and people directly rather than just the air. This not only makes the heating experience more comfortable but also reduces energy consumption. Furthermore, the CGN18RA is designed with an adjustable thermostat to provide precise temperature control, allowing users to set their desired warmth levels easily.

On the other hand, the CGN30D offers a more robust heating solution with an output of up to 30,000 BTUs. This model is particularly suited for larger spaces, effectively warming garages, workshops, or open-plan living areas. Like the CGN18RA, the CGN30D utilizes direct infrared heating technology, ensuring efficient and consistent temperatures are maintained. Users appreciate the dual-fuel capability of the CGN30D, allowing it to operate on both natural gas and propane, which adds to its versatility and convenience.

Both models prioritize safety, featuring built-in mechanisms such as tip-over shut-off systems and automatic shut-off valves to prevent potential hazards. Furthermore, the units are constructed with durable materials that withstand regular use while maintaining sleek designs. Portability is another advantage, with easy-to-move structures allowing users to reposition heaters according to their heating requirements.

In summary, Desa CGN18RA and CGN30D are impressive space heaters characterized by their powerful heating capabilities, energy efficiency, and user-friendly features. Their advanced technology, safety mechanisms, and versatility in fuel options make them outstanding choices for anyone looking to maintain a comfortable environment, whether at home or in a commercial space. With these models, users can enjoy reliable warmth and comfort during the colder months.