Desa CGN18RA, CGN30D installation manual Control Position Label Hardware Assembly

Page 31

PARTS LIST

Model CGN30D

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

098304-01

Screw, #10 x 3/8"

2

2

098742-03

Front Panel

1

3

098238-07

Grill Guard

1

4

101108-01

Clip-Grill Guard

2

5

098198-04

Apron

1

6

M11084-26

Screw, #10 x 3/8"

9

7

098462-01

Control Rod Assembly

1

8

098457-02

Reflector Assembly

1

9

098867-05

Regulator

1

10

M11084-38

Screw, #8 x 3/8"

2

11

098456-03

Cabinet Assembly

1

12

098324-01

Control Knob

1

13

See Detail

Burner Assembly

1

13-1

099218-02

Burner

1

13-2

098508-01

Valve Retainer Nut

1

13-3

099056-02

Injector

5

13-4

099052-01

Tubing-Valve to Plaque B & D

1

13-5

099053-01

Tubing-Valve to Plaque C

1

13-6

099057-01

Pressure Tap Fitting

1

13-7

099054-01

Tubing-Valve to Plaque A & E

1

13-8

098932-06

Control Valve

1

13-9

099051-02

Inlet Tubing

1

13-10

099045-01

Pilot Tubing-Valve to Regulator

1

13-11

099059-01

ODS/Pilot

1

13-12

M11084-37

Screw, #8 x 1/4"

5

13-13

099047-02

Pilot Tubing-Regulator to Pilot

1

13-14

099918-01

Pilot Regulator

1

13-15

M11084-26

Screw, #10 x 3/8"

2

13-16

098593-01

Thermocouple

1

13-17

098594-01

Ignitor Electrode

1

13-18

098276-01

Plug, 1/8

 

14

099066-01

Mounting Bracket

1

15

100537-01

Regulator Bracket

1

16

098325-01

Roll Pin

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

100822-01 Control Position Label

100642-01 Hardware Assembly

1

1

101826

31

Image 31
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Safety Device Local Codes Unpacking Product FeaturesPiezo Ignition System Ventilation AIR for CombustionProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Appliances in both spaces AIR forVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeInstalling to Wall Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsCGN30D Connecting to GAS SupplyServicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsWhat to do if YOU Smell GAS HeaterPilot Operating HeaterTo Select Heating Level Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterGRH/OV 019A ODS/PILOT and Burner Orifice CleaningMaintenance Trouble ShootingTROUBLE- Shooting See CleaningSee Cleaning and Main Technical ServiceHints Replacement PartsParts Under Warranty Parts Not Under WarrantyValve GA5010 AccessoriesCentrals FAN Kits GA3100, GA3100A, and GA3200TAModel CGN18RA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListModel CGN30D Control Position Label Hardware Assembly Keep this Warranty Warranty Information

CGN30D, CGN18RA specifications

Desa CGN18RA and CGN30D are two advanced space heaters designed for both residential and commercial use. These models are well-regarded for their innovative features, technologies, and exceptional performance, making them suitable choices for various heating needs, particularly in larger spaces.

The CGN18RA is equipped with several key features that enhance its functionality. It boasts a reliable heat output of approximately 18,000 BTUs, ensuring effective warmth during cold months. This model utilizes infrared technology, which enables it to heat objects and people directly rather than just the air. This not only makes the heating experience more comfortable but also reduces energy consumption. Furthermore, the CGN18RA is designed with an adjustable thermostat to provide precise temperature control, allowing users to set their desired warmth levels easily.

On the other hand, the CGN30D offers a more robust heating solution with an output of up to 30,000 BTUs. This model is particularly suited for larger spaces, effectively warming garages, workshops, or open-plan living areas. Like the CGN18RA, the CGN30D utilizes direct infrared heating technology, ensuring efficient and consistent temperatures are maintained. Users appreciate the dual-fuel capability of the CGN30D, allowing it to operate on both natural gas and propane, which adds to its versatility and convenience.

Both models prioritize safety, featuring built-in mechanisms such as tip-over shut-off systems and automatic shut-off valves to prevent potential hazards. Furthermore, the units are constructed with durable materials that withstand regular use while maintaining sleek designs. Portability is another advantage, with easy-to-move structures allowing users to reposition heaters according to their heating requirements.

In summary, Desa CGN18RA and CGN30D are impressive space heaters characterized by their powerful heating capabilities, energy efficiency, and user-friendly features. Their advanced technology, safety mechanisms, and versatility in fuel options make them outstanding choices for anyone looking to maintain a comfortable environment, whether at home or in a commercial space. With these models, users can enjoy reliable warmth and comfort during the colder months.