OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step.

5.Press in control knob.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

6.Keep control knob pressed in and turn it counterclockwise C-clockwiseto the

PILOT/IGN position. This will light pilot.

Note: You will hear a loud “click” when the control knob reaches the PILOT/IGN position.

If pilot does not light

turn control knob clockwise Clockwise to the OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, pages 22 through 25

contact a qualified service person or gas supplier for repairs

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 20.

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 16 - Pilot

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

101826

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Local Codes Unpacking Product Features Safety DevicePiezo Ignition System AIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion and Ventilation Determining AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building AIR forVentilation AIR Appliances in both spacesVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Installing To WallInstallation Items Locating HeaterInstalling to Wall Removing Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply CGN30DConnections Pressure Testing GAS Supply Piping SystemChecking GAS Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotTo Select Heating Level Shutting Off Heater Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off Burner Only pilot stays litGRH/OV 019A Trouble Shooting CleaningMaintenance ODS/PILOT and Burner OrificeSee Cleaning TROUBLE- ShootingSee Cleaning and Main Service TechnicalParts Not Under Warranty Replacement PartsParts Under Warranty HintsFAN Kits GA3100, GA3100A, and GA3200TA AccessoriesCentrals Valve GA5010Illustrated Parts Breakdown Model CGN18RAParts List KEY Part Number Description QTYModel CGN30D Control Position Label Hardware Assembly Warranty Information Keep this Warranty

CGN30D, CGN18RA specifications

Desa CGN18RA and CGN30D are two advanced space heaters designed for both residential and commercial use. These models are well-regarded for their innovative features, technologies, and exceptional performance, making them suitable choices for various heating needs, particularly in larger spaces.

The CGN18RA is equipped with several key features that enhance its functionality. It boasts a reliable heat output of approximately 18,000 BTUs, ensuring effective warmth during cold months. This model utilizes infrared technology, which enables it to heat objects and people directly rather than just the air. This not only makes the heating experience more comfortable but also reduces energy consumption. Furthermore, the CGN18RA is designed with an adjustable thermostat to provide precise temperature control, allowing users to set their desired warmth levels easily.

On the other hand, the CGN30D offers a more robust heating solution with an output of up to 30,000 BTUs. This model is particularly suited for larger spaces, effectively warming garages, workshops, or open-plan living areas. Like the CGN18RA, the CGN30D utilizes direct infrared heating technology, ensuring efficient and consistent temperatures are maintained. Users appreciate the dual-fuel capability of the CGN30D, allowing it to operate on both natural gas and propane, which adds to its versatility and convenience.

Both models prioritize safety, featuring built-in mechanisms such as tip-over shut-off systems and automatic shut-off valves to prevent potential hazards. Furthermore, the units are constructed with durable materials that withstand regular use while maintaining sleek designs. Portability is another advantage, with easy-to-move structures allowing users to reposition heaters according to their heating requirements.

In summary, Desa CGN18RA and CGN30D are impressive space heaters characterized by their powerful heating capabilities, energy efficiency, and user-friendly features. Their advanced technology, safety mechanisms, and versatility in fuel options make them outstanding choices for anyone looking to maintain a comfortable environment, whether at home or in a commercial space. With these models, users can enjoy reliable warmth and comfort during the colder months.