Desa VP1000BA Operating Heater Inspecting Burner, Pilot Flame Pattern, Shutting Off Heater

Page 18

OPERATING HEATER

Continued

INSPECTING BURNER

18

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

 

 

 

 

Shutting Off Heater

1.

Turn control knob clockwise Clockwise to the PILOT position.

2.

Press in control knob and turn clockwise Clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1.Remove front panel (see Figure 10, page 12).

2.Follow steps 1 through 5 under Lighting Instructions, pages 16 and 17.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 seconds, release control knob.

5.Replace front panel.

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Pilot Burner

Thermocouple

GOOD PILOT/LP

GRH/OV 007

Figure 18 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

BAD PILOT/LP

GRH/OV 008

Figure 19 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance, above)

see Troubleshooting, pages 20 through 23

Continued

101869

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Product Identification Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemUnusually Tight Construction Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply External Regulator With Vent Pointing DownConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping System Pressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterControl knob and turn counterclockwise C-clockwise Shutting Off Heater Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off Burner Only pilot stays litBurner Flame Pattern Model VP600B will be lower due to lower input ratingCleaning and Maintenance Trouble Shooting ODS/PILOT and Burner OrificeCabinet See Cleaning TROUBLE- ShootingCleaning and Mainte Ing statement at TopTechnical Service Service HintsVP1000BA VP600B Parts Not Under Warranty Replacement Parts Service Publications AccessoryParts Under Warranty Valve GA5010Heater Exploded View Parts List VP1000BA Model VP600B Parts List VP600B 101869 101869 Warranty Information Keep this Warranty