Desa installation manual Technical Service, Service Hints, VP1000BA VP600B

Page 24

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

24

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VP1000BA

VP600B

BTU (Variable)

5,000/10,000

4,400/6,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

 

Heater

13.5

13.5

Shipping

16.5

16.5

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

101869

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR for Combustion and Ventilation Producing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply External Regulator With Vent Pointing DownConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterControl knob and turn counterclockwise C-clockwise Operating Heater Inspecting Burner Pilot Flame PatternShutting Off Heater Shutting Off Burner Only pilot stays litBurner Flame Pattern Model VP600B will be lower due to lower input ratingCleaning and Maintenance Trouble Shooting ODS/PILOT and Burner OrificeCabinet See Cleaning TROUBLE- ShootingCleaning and Mainte Ing statement at TopTechnical Service Service HintsVP1000BA VP600B Replacement Parts Service Publications Accessory Parts Under WarrantyParts Not Under Warranty Valve GA5010Heater Exploded View Parts List VP1000BA Model VP600B Parts List VP600B 101869 101869 Warranty Information Keep this Warranty