INSPECTING BURNER

Continued

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

WARNING

WARNING ICON

G 001

If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame.

1/2 GLASS HEIGHT

(Model VP1000BA)

CORRECT FLAME PATTERN

AT HIGH POSITION

(Model VP600B will be lower due to lower input rating)

Figure 20 - Correct Burner Flame Pattern

Yellow

Tipping

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 21 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 18)

see Troubleshooting, pages 20 through 23

19

101869

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRCheck GAS Type Installation ItemsLocating Heater Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingControl knob and turn counterclockwise C-clockwise Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterModel VP600B will be lower due to lower input rating Burner Flame PatternODS/PILOT and Burner Orifice Cleaning and Maintenance Trouble ShootingCabinet TROUBLE- Shooting See CleaningCleaning and Mainte Top Ing statement atService Hints Technical ServiceVP1000BA VP600B Valve GA5010 Replacement Parts Service Publications AccessoryParts Under Warranty Parts Not Under WarrantyHeater Exploded View Parts List VP1000BA Model VP600B Parts List VP600B 101869 101869 Keep this Warranty Warranty Information