Desa Tech GCH480 manual Shutdown Instructions, Storage, Moving and Positioning Heater

Page 11

PROPANE CONSTRUCTION HEATER

SHUTDOWN INSTRUCTIONS

1.push in gas control knob slightly and turn clockwise to “off” position. do not force. (a)

2.Turn gas supply off by turning propane tank valve clockwise to close.

Turning burner only OFF (pilot stays lit).

Turn control knob clockwise to “piloT” position. (B)

STORAGE

never store a propane gas tank inside a building or in the vicinity of any gas or oil burning appliance. when the propane tank is not disconnected from the construction heater, the gas tank and heater must be stored outdoors in a well ventilated area, out of the reach of children. if for any reason the heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well ventilated area out of reach of children, in accordance with the standard for the the storage and handling of liquefied petroleum gases, ansi / nfpa 58 and csa B149.1, natural gas and propane installation code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater.

MOVING AND POSITIONING HEATER

There is a brake in each of the front wheels of your heater that helps keep it in place when in use. To engage the brakes, push the lever down on each wheel. To move the heater, release the brakes, simply by flipping the levers on both brakes up.

11

Image 11
Contents Wash hands after handling Propane Construction Heater Radiant Propane Construction Heaters General Safety InformationImportant Safety Information General Safety InstructionsPage Unpacking the Heater Propane Supply Connectingunpackingtothegasheatersupply Checking for Leaks Propane SafetyLighting Instructions Moving and Positioning Heater Shutdown InstructionsStorage Pilot and Burning Inspection MaintenanceProblem Possible Cause What To Do TroubleshootingTroubleshooting Limited Warranty WarrantyWarranty Registration Gch480RA18 Series Replacement Parts ListExploded Parts Drawing Se laver les mains après toute manipulation Índice Calentadores radiantes para construcción a propano Información General Sobre SeguridadInformación Importante Sobre Seguridad Instrucciones Generales Sobre SeguridadPage FIgURA Desembalaje DEL CalentadorSuministro DE Propano Conexión AL Suministro DE GAS PrecauciónBúsqueda DE Fugas Seguridad DEL PropanoInstrucciones Para EL Encendido Movimiento Y Colocación DEL Calentador Instrucciones DE ApagadoAlmacenaje Inspección del piloto y del encendido MantenimientoProblema Causa Posible Solución DE ProblemasProblema Causa Posible ¿Qué debo hacer? Solución DE Problemas continuaciónGarantía Limitada GarantíaRegistro DE Garantía Lista DE Piezas DE Repuesto Gch480Dibujo DE Despiece Lávese las manos después de su manipulación TAbLE DES Matières Important Consignes de sécurité Consignes de séCurité généralesConsignes de séCurité iMPortantes Page DéBallage du radiateur AliMentation en ProPane Tuyau ET Régulateur RaCCordeMent de l’aliMentation en gaZVériFiCation des Fuites AVertisseMents de séCurité au suJet du ProPaneInstruCtions Pour l’alluMage RangeMent DéPlaCeMent et PositionneMent du radiateurInstruCtions Pour l’arrÊt Inspection de la veilleuse et du brûleur EntretienProblème Cause possible Mesures à prendre DéPannageDéPannage suite Garantie Restreinte GarantieEnregistrement DE LA Garantie Série RA18 Liste des PiÈCes de reCHangeSCHéMa éClaté des PiÈCes

GCH480 specifications

The Desa Tech GCH480 is an advanced gas-powered heater that exemplifies innovation in heating technology. Designed with efficiency and user-friendliness in mind, the GCH480 is ideal for both residential and commercial applications.

One of its standout features is the high heat output, which provides effective warmth in large areas. With an impressive heating capacity, this unit can efficiently heat spaces up to 1,200 square feet, making it perfect for workshops, garages, or even open living areas. The GCH480 operates on natural gas, which is not only economical but also environmentally friendly compared to other fossil fuels.

The GCH480 incorporates advanced safety features, including an automatic shut-off mechanism that activates in the event of a malfunction. This ensures that users can have peace of mind while using the heater, knowing that safety is a top priority. Additionally, it features a built-in oxygen depletion sensor that automatically turns off the heater if oxygen levels drop below safe thresholds.

An important characteristic of the GCH480 is its sleek and compact design, which allows for easy placement in various settings. It can be mounted on walls or used as a portable unit, adapting to your specific heating needs. Its user-friendly interface, complete with an adjustable thermostat, allows for precise control over the heating settings, ensuring optimum comfort at all times.

The heater utilizes forced air technology, which rapidly circulates warm air throughout the space, eliminating cold spots and providing even heat distribution. This technology not only increases efficiency but also reduces energy consumption, enabling users to save on their utility bills.

Furthermore, the Desa Tech GCH480 is built with durable materials designed to withstand the rigors of daily usage. Its robust construction assures longevity, making it a worthwhile investment for those seeking reliable heating solutions.

In conclusion, the Desa Tech GCH480 gas-powered heater combines efficiency, safety, and convenience in one package. With its impressive heating capacity, advanced safety features, and user-friendly design, it stands out as an exceptional choice for anyone looking to enhance their heating system. Whether in a home or commercial environment, the GCH480 promises reliable performance and lasting comfort.