Desa Tech GCH480 manual Propane Supply

Page 7

PROPANE CONSTRUCTION HEATER

PROPANE SUPPLY

you must provide the propane gas and cylinder(s). use this heater only with a propane vapor withdrawal supply system. Refer to chapter 5 of the standard for storage and handling of liquefied petroleum gas, ansi/nfpa 58. your local library or fire department will have this booklet.

The cylinder must be equipped with a collar to protect the gas valve, an arrangement of vapor withdrawal, a shutoff valve terminating the cylinder valve outlet as specified in the american national standard for compressed gas cylinder valve outlet and inlet connections, and a safety relief valve in direct contact with the vapor space of the tank.

always keep the cylinder in an upright position. avoid knocking the cylinder over on its side with the hose/ regulator connected, as this can cause damage to the regulator diaphragm.

never store a propane (lp) cylinder indoors or in the vicinity of any gas burning appliances.

protect the cylinder valve, and handle it with care.

Be sure that the shut-off valve is closed tightly after each use.

Be sure to protect the pol fitting from damage when disconnected. damage to this fitting can lead to leaks.

The hose assembly shall be visually inspected prior to each use of the heater. if it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer.

never connect an unregulated cylinder to the heater. always use the hose and regulator supplied.

never use any other hose and regulator.

do not subject the cylinder to excessive heat.

7

Image 7
Contents Wash hands after handling Propane Construction Heater Radiant Propane Construction Heaters General Safety InformationImportant Safety Information General Safety InstructionsPage Unpacking the Heater Propane Supply Connectingunpackingtothegasheatersupply Checking for Leaks Propane SafetyLighting Instructions Storage Shutdown InstructionsMoving and Positioning Heater Pilot and Burning Inspection MaintenanceProblem Possible Cause What To Do TroubleshootingTroubleshooting Limited Warranty WarrantyWarranty Registration Gch480RA18 Series Replacement Parts ListExploded Parts Drawing Se laver les mains après toute manipulation Índice Calentadores radiantes para construcción a propano Información General Sobre SeguridadInformación Importante Sobre Seguridad Instrucciones Generales Sobre SeguridadPage FIgURA Desembalaje DEL CalentadorSuministro DE Propano Conexión AL Suministro DE GAS PrecauciónBúsqueda DE Fugas Seguridad DEL PropanoInstrucciones Para EL Encendido Almacenaje Instrucciones DE ApagadoMovimiento Y Colocación DEL Calentador Inspección del piloto y del encendido MantenimientoProblema Causa Posible Solución DE ProblemasProblema Causa Posible ¿Qué debo hacer? Solución DE Problemas continuaciónGarantía Limitada GarantíaRegistro DE Garantía Lista DE Piezas DE Repuesto Gch480Dibujo DE Despiece Lávese las manos después de su manipulación TAbLE DES Matières Important Consignes de sécurité Consignes de séCurité généralesConsignes de séCurité iMPortantes Page DéBallage du radiateur AliMentation en ProPane Tuyau ET Régulateur RaCCordeMent de l’aliMentation en gaZVériFiCation des Fuites AVertisseMents de séCurité au suJet du ProPaneInstruCtions Pour l’alluMage InstruCtions Pour l’arrÊt DéPlaCeMent et PositionneMent du radiateurRangeMent Inspection de la veilleuse et du brûleur EntretienProblème Cause possible Mesures à prendre DéPannageDéPannage suite Garantie Restreinte GarantieEnregistrement DE LA Garantie Série RA18 Liste des PiÈCes de reCHangeSCHéMa éClaté des PiÈCes

GCH480 specifications

The Desa Tech GCH480 is an advanced gas-powered heater that exemplifies innovation in heating technology. Designed with efficiency and user-friendliness in mind, the GCH480 is ideal for both residential and commercial applications.

One of its standout features is the high heat output, which provides effective warmth in large areas. With an impressive heating capacity, this unit can efficiently heat spaces up to 1,200 square feet, making it perfect for workshops, garages, or even open living areas. The GCH480 operates on natural gas, which is not only economical but also environmentally friendly compared to other fossil fuels.

The GCH480 incorporates advanced safety features, including an automatic shut-off mechanism that activates in the event of a malfunction. This ensures that users can have peace of mind while using the heater, knowing that safety is a top priority. Additionally, it features a built-in oxygen depletion sensor that automatically turns off the heater if oxygen levels drop below safe thresholds.

An important characteristic of the GCH480 is its sleek and compact design, which allows for easy placement in various settings. It can be mounted on walls or used as a portable unit, adapting to your specific heating needs. Its user-friendly interface, complete with an adjustable thermostat, allows for precise control over the heating settings, ensuring optimum comfort at all times.

The heater utilizes forced air technology, which rapidly circulates warm air throughout the space, eliminating cold spots and providing even heat distribution. This technology not only increases efficiency but also reduces energy consumption, enabling users to save on their utility bills.

Furthermore, the Desa Tech GCH480 is built with durable materials designed to withstand the rigors of daily usage. Its robust construction assures longevity, making it a worthwhile investment for those seeking reliable heating solutions.

In conclusion, the Desa Tech GCH480 gas-powered heater combines efficiency, safety, and convenience in one package. With its impressive heating capacity, advanced safety features, and user-friendly design, it stands out as an exceptional choice for anyone looking to enhance their heating system. Whether in a home or commercial environment, the GCH480 promises reliable performance and lasting comfort.