OPERATING HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During initial operation of new heater, burning logs will give off a paper- burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

Ignitor Button

 

Control Knob

 

HI

PILOT

 

 

 

 

OFF

 

LO

 

Figure 20 - Control Knob and Ignitor Button Location

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

101992

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceOperation Piezo Ignition SystemAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Check GAS TypeMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Accessories, Minimum Non Combustible Material ClearancesMinimum clearances shown in when using hood Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Attaching Mounting Brackets to HeaterExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Front LogOperating Heater Operating Heater Thermostat-Controlled Models OnlyFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning and Maintenance Trouble ShootingODS/PILOT and Burners Cleaning and Mainte TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Optional Positioning Thermostat Sensing Bulb Technical Service Service HintsCG3324PT CG3630PT CG2618PV CG3324PV CG3630PVParts Not Under Warranty Replacement Parts CentralsParts Under Warranty Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Break Down Parts List Description QTYThermostat Controlled Models Description Warranty Information Keep this Warranty

CG2618PV, CG3630PT, CG3324PT, CG3324PV, CG3630PV specifications

Desa Tech has made significant strides in the heating and appliance industry with its innovative line of products, featuring the CG3630PV, CG3324PV, CG3324PT, CG3630PT, and CG2618PV models. Each of these models offers unique features, cutting-edge technologies, and characteristics designed to meet diverse customer needs while ensuring efficiency and reliability.

The CG3630PV is a versatile model that stands out with its powerful heating capacity, ideal for larger spaces. It utilizes advanced combustion technology that maximizes heat output while minimizing fuel consumption. This model is also equipped with an easy-to-use digital thermostat, allowing users to set their desired temperature with precision.

In contrast, the CG3324PV model is tailored for mid-sized areas. It features a sleek design that blends seamlessly with modern home decor. One of its key characteristics is the eco-friendly design that operates efficiently, reducing carbon emissions while still providing adequate warmth. The CG3324PV incorporates an automatic ignition system, eliminating the hassle of manual lighting.

The CG3324PT model takes a different approach by offering multi-fuel capabilities. Users can choose between propane and natural gas, making it a flexible option for various needs. This model also boasts a compact design, perfect for smaller rooms or confined spaces, without compromising on heat output.

For those looking for a robust option, the CG3630PT offers impressive thermal efficiency and a higher heat output, making it suitable for large living areas or workshops. This model includes a safety shut-off feature that provides peace of mind, ensuring the heater turns off in the event of overheating or other malfunctions.

Finally, the CG2618PV model is designed with portability in mind. It offers a lightweight construction, making it easy to move from room to room as needed. Equipped with a strong heating element and a user-friendly control panel, this model is perfect for quick heating solutions without the need for permanent installation.

Collectively, these models represent Desa Tech's commitment to innovation, user-friendly features, and environmental responsibility, making them excellent choices for consumers seeking reliable heating solutions. With various options tailored to different needs, customers can confidently select the right heater for their home or workspace.