Desa Tech CG3324PV, CG2618PV, CG3630PV, CG3324PT Optional Positioning Thermostat Sensing Bulb

Page 28
Figure 32 - Positioning the Thermostat Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
Thermostat
Sensing Bulb
Adhesive-backed Mounting Clip
Figure 29 - Locating Thermostat Sensing Bulb on Masonry Fireplace
If you have a factory-built metal fireplace, see Figure 29 for location.
Thermostat
Sensing Bulb
Adhesive-backed Mounting Clip
Figure 30 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 31).
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Glass
Doors
Figure 31 - Installing Thermostat Sensing Bulb behind Glass Doors

OPTIONAL

POSITIONING

OF THERMOSTAT

SENSING BULB

For Masonry and

Factory-built

Metal Fireplace

Continued

5. The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 32). Slide

the thermostat sensing bulb into the clip.

 

IMPORTANT: Do not crimp capillary.

Thermostat

 

Sensing Bulb

 

Adhesive-backed

Capillary

Mounting Clip

 

 

Do Not Crimp Capillary

28

101992

Image 28
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceOperation Piezo Ignition SystemAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsMinimum Wall and Ceiling Clearances see Figure Accessories, Minimum Non Combustible Material ClearancesMinimum clearances shown in when using hood Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Attaching Mounting Brackets to HeaterExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Front LogOperating Heater Operating Heater Thermostat-Controlled Models OnlyPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern ODS/PILOT and Burners Cleaning and Maintenance Trouble ShootingLogs Cleaning and Mainte TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Optional Positioning Thermostat Sensing Bulb Technical Service Service HintsCG3324PT CG3630PT CG2618PV CG3324PV CG3630PVParts Under Warranty Replacement Parts CentralsParts Not Under Warranty Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Break Down Parts List Description QTYThermostat Controlled Models Description Warranty Information Keep this Warranty

CG2618PV, CG3630PT, CG3324PT, CG3324PV, CG3630PV specifications

Desa Tech has made significant strides in the heating and appliance industry with its innovative line of products, featuring the CG3630PV, CG3324PV, CG3324PT, CG3630PT, and CG2618PV models. Each of these models offers unique features, cutting-edge technologies, and characteristics designed to meet diverse customer needs while ensuring efficiency and reliability.

The CG3630PV is a versatile model that stands out with its powerful heating capacity, ideal for larger spaces. It utilizes advanced combustion technology that maximizes heat output while minimizing fuel consumption. This model is also equipped with an easy-to-use digital thermostat, allowing users to set their desired temperature with precision.

In contrast, the CG3324PV model is tailored for mid-sized areas. It features a sleek design that blends seamlessly with modern home decor. One of its key characteristics is the eco-friendly design that operates efficiently, reducing carbon emissions while still providing adequate warmth. The CG3324PV incorporates an automatic ignition system, eliminating the hassle of manual lighting.

The CG3324PT model takes a different approach by offering multi-fuel capabilities. Users can choose between propane and natural gas, making it a flexible option for various needs. This model also boasts a compact design, perfect for smaller rooms or confined spaces, without compromising on heat output.

For those looking for a robust option, the CG3630PT offers impressive thermal efficiency and a higher heat output, making it suitable for large living areas or workshops. This model includes a safety shut-off feature that provides peace of mind, ensuring the heater turns off in the event of overheating or other malfunctions.

Finally, the CG2618PV model is designed with portability in mind. It offers a lightweight construction, making it easy to move from room to room as needed. Equipped with a strong heating element and a user-friendly control panel, this model is perfect for quick heating solutions without the need for permanent installation.

Collectively, these models represent Desa Tech's commitment to innovation, user-friendly features, and environmental responsibility, making them excellent choices for consumers seeking reliable heating solutions. With various options tailored to different needs, customers can confidently select the right heater for their home or workspace.