Desa Tech CG3324PV, CG2618PV, CG3630PV, CG3324PT, CG3630PT installation manual Safety Information

Page 3

SAFETY INFORMATION

Continued

WARNINGS Continued

WARNING: Any change to this heater or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

7.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

8.You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking may occur due to log curing and heater burning manufacturing residues.

10.Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans may create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

11.Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

12.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8. If heater keeps shutting off, see Troubleshooting, pages 23 through 26.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Never place any objects on the heater.

16.Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.

17.Carefully supervise young children when they are in the room with heater.

18.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

19.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

20.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

21.Operating heater above elevations of 4,500 feet may cause pilot outage.

3

101992

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device OperationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallingMinimum Fireplace Clearance To Combustible Materials LOG Sizing RequirementsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Accessories,Minimum clearances shown in when using hood Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Mounting Brackets to Heater Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsInstalling Front Log Installing LogsOperating Heater Thermostat-Controlled Models Only Operating HeaterInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning and Maintenance Trouble Shooting ODS/PILOT and BurnersLogs TROUBLE- Shooting Cleaning and MainteRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Optional Positioning Thermostat Sensing Bulb CG2618PV CG3324PV CG3630PV Technical ServiceService Hints CG3324PT CG3630PTReplacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Break Down Description QTY Parts ListThermostat Controlled Models Description Keep this Warranty Warranty Information

CG2618PV, CG3630PT, CG3324PT, CG3324PV, CG3630PV specifications

Desa Tech has made significant strides in the heating and appliance industry with its innovative line of products, featuring the CG3630PV, CG3324PV, CG3324PT, CG3630PT, and CG2618PV models. Each of these models offers unique features, cutting-edge technologies, and characteristics designed to meet diverse customer needs while ensuring efficiency and reliability.

The CG3630PV is a versatile model that stands out with its powerful heating capacity, ideal for larger spaces. It utilizes advanced combustion technology that maximizes heat output while minimizing fuel consumption. This model is also equipped with an easy-to-use digital thermostat, allowing users to set their desired temperature with precision.

In contrast, the CG3324PV model is tailored for mid-sized areas. It features a sleek design that blends seamlessly with modern home decor. One of its key characteristics is the eco-friendly design that operates efficiently, reducing carbon emissions while still providing adequate warmth. The CG3324PV incorporates an automatic ignition system, eliminating the hassle of manual lighting.

The CG3324PT model takes a different approach by offering multi-fuel capabilities. Users can choose between propane and natural gas, making it a flexible option for various needs. This model also boasts a compact design, perfect for smaller rooms or confined spaces, without compromising on heat output.

For those looking for a robust option, the CG3630PT offers impressive thermal efficiency and a higher heat output, making it suitable for large living areas or workshops. This model includes a safety shut-off feature that provides peace of mind, ensuring the heater turns off in the event of overheating or other malfunctions.

Finally, the CG2618PV model is designed with portability in mind. It offers a lightweight construction, making it easy to move from room to room as needed. Equipped with a strong heating element and a user-friendly control panel, this model is perfect for quick heating solutions without the need for permanent installation.

Collectively, these models represent Desa Tech's commitment to innovation, user-friendly features, and environmental responsibility, making them excellent choices for consumers seeking reliable heating solutions. With various options tailored to different needs, customers can confidently select the right heater for their home or workspace.