Desa Tech CG3324PV Installing Damper Clamp Accessory for Vented Operation, Attaching Damper Clamp

Page 13

INSTALLING

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of non combustible material.

If your heater is a manually controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 31). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various Standard Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

Damper

Clamp

Damper

Damper

Clamp

Damper

Damper

Masonry Fireplace

Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

13

101992

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesOperation Piezo Ignition SystemProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallingLOG Sizing Requirements Minimum Fireplace Clearance To Combustible MaterialsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Accessories,Minimum clearances shown in when using hood Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Mounting Brackets to Heater Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsInstalling Front Log Installing LogsOperating Heater Thermostat-Controlled Models Only Operating HeaterPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern ODS/PILOT and Burners Cleaning and Maintenance Trouble ShootingLogs TROUBLE- Shooting Cleaning and MainteRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Optional Positioning Thermostat Sensing Bulb Service Hints Technical ServiceCG3324PT CG3630PT CG2618PV CG3324PV CG3630PVParts Under Warranty Replacement Parts CentralsParts Not Under Warranty Valve GA5010 AccessoriesHood GA6050 Hood GA6052Illustrated Parts Break Down Description QTY Parts ListThermostat Controlled Models Description Keep this Warranty Warranty Information

CG2618PV, CG3630PT, CG3324PT, CG3324PV, CG3630PV specifications

Desa Tech has made significant strides in the heating and appliance industry with its innovative line of products, featuring the CG3630PV, CG3324PV, CG3324PT, CG3630PT, and CG2618PV models. Each of these models offers unique features, cutting-edge technologies, and characteristics designed to meet diverse customer needs while ensuring efficiency and reliability.

The CG3630PV is a versatile model that stands out with its powerful heating capacity, ideal for larger spaces. It utilizes advanced combustion technology that maximizes heat output while minimizing fuel consumption. This model is also equipped with an easy-to-use digital thermostat, allowing users to set their desired temperature with precision.

In contrast, the CG3324PV model is tailored for mid-sized areas. It features a sleek design that blends seamlessly with modern home decor. One of its key characteristics is the eco-friendly design that operates efficiently, reducing carbon emissions while still providing adequate warmth. The CG3324PV incorporates an automatic ignition system, eliminating the hassle of manual lighting.

The CG3324PT model takes a different approach by offering multi-fuel capabilities. Users can choose between propane and natural gas, making it a flexible option for various needs. This model also boasts a compact design, perfect for smaller rooms or confined spaces, without compromising on heat output.

For those looking for a robust option, the CG3630PT offers impressive thermal efficiency and a higher heat output, making it suitable for large living areas or workshops. This model includes a safety shut-off feature that provides peace of mind, ensuring the heater turns off in the event of overheating or other malfunctions.

Finally, the CG2618PV model is designed with portability in mind. It offers a lightweight construction, making it easy to move from room to room as needed. Equipped with a strong heating element and a user-friendly control panel, this model is perfect for quick heating solutions without the need for permanent installation.

Collectively, these models represent Desa Tech's commitment to innovation, user-friendly features, and environmental responsibility, making them excellent choices for consumers seeking reliable heating solutions. With various options tailored to different needs, customers can confidently select the right heater for their home or workspace.