Charnwood DX20i MkII Preparation Fireplace, Fitting the Fire, HOT Water System

Page 8

appliance. In some situations it may be necessary to shield the beam or mantelpiece to protect it.

PREPARATION OF

FIREPLACE

Before fitting the appliance into an existing fireplace remove the fireback and any loose in-fill material.

The hearth, surround and opening for the appliance must conform with Figs. 5 and 6. The flat area around the opening must be a minimum of 750 mm wide and 660 mm high. Ensure that the hearth and the base in the opening are flat, level, and at right angles to the surround.

Make a hole in the front of the chimney breast to give access for infilling and fixing the flue pipe. If the optional boiler is to be fitted it will also be necessary to make a hole in the side of the chimney breast to give access for the pipework.

FITTING THE FIRE

In some cases it may be necessary to place the connecting flue pipe in the chimney before fitting the fire into the fireplace.

Apply fire cement to the rear face of the sealing flange on the appliance. Fit the appliance into the opening ensuring that it is central and that a good seal is made between the sealing flange and the face of the surround.

Remove any excess fire cement from around the sealing flange.

The appliance should be screwed to the hearth through the holes at the base of the sealing flange.

HOT WATER SYSTEM

The optional add-in boiler which may be fitted in the appliance has an

This Dimension IsThe

Minimum Level Area

Required To Enable The

Ashpit Door To Be

Opened.

For Overall Sizes Of

Hearth See The

Section Titled "Hearth".

265 mm Minimum

400 mm

Minimum

Fig. 4. Limiting Dimensions

Of Hearth

The shaded area on the face of the surround is the minimum flat area required.

750 mm

660 mm

Dim. A:

Max. 470mm (18 1/2")

Min. 405mm (16")

Dim. B:

Max. 575mm (22 2/3")

Min. 555mm (21 3/4")

Fig. 5. Limiting Dimensions Of

Surround And Opening

output sufficient for domestic hot water heating. If the boiler is fitted then the room heating will be reduced.

The hot water system should be a gravity circuit and must be correctly vented as shown in Fig. 6.

A double feed indirect hot water

Page 8

storage cylinder to BS:1566 part 1 should be used in most situations, unless the appliance is to be fitted in a soft water area in which case a direct hot water cylinder may be used provided that the boiler is glass lined.

All pipework in the primary circuit must be 28mm diameter and the flow pipe must rise continuously from the boiler to the open vent.

If an indirect cylinder is used then the primary circuit should be filled with a suitable inhibitor to prevent the build up of scale and corrosion.

FITTING THE

OPTIONAL ADD-IN

BOILER

The boiler replaces the rear firebrick and is reversible so that the 1" B.S.P. male tappings may come on either the left or the right hand side of the boiler.

The boiler tappings protrude from the sides of the appliance and it will therefore be necessary to fit the boiler into the appliance after positioning the appliance in the fireplace if the fire surround is already fitted.

Before fitting the boiler, remove the front firebars, the side and back fire plates and the firebricks. Knock out the knock-outs for the boiler tappings on the appropriate side of the firebox.

Remove the backnuts and fibre washers from the boiler tappings and fit the boiler into the appliance. Place the fibre washers over the tappings on the outside of the appliance and fit the backnuts, ensuring that the boiler is held tightly against the rear inside face of the appliance and that the top edge of the boiler is level or runs uphill to the flow tapping.

When re-fitting the firebricks, note that the short side firebrick supplied with the boiler must be fitted on the

HV 7/96

Image 8
Contents Charnwood Operating Instructions for General PointsFuels Door OperationMultifuel Grate LightingControlling Fire Running the Fire with the Doors OpenASH Clearance RefuellingOvernight Burning RiddlingThroat Plate and Flueway Cleaning Special Points When Burning CoalCleaning Maintenance Trouble ShootingFire Blazing Out Control Over-FiringFume Emission Door Glass Blacks UpHealth and Safety Precautions InstructionsPerformance ChimneyPreparation Fireplace Fitting the FireHOT Water System Fitting Optional ADD-IN BoilerTypical Hot Water System Using Indirect Hot Water Cylinder Flue Connection InfillingAssembly ThermostatPRE Lighting Check CommissioningCharnwood DX20i MkII Overall Dimensions

DX20i MkII specifications

The Charnwood DX20i MkII is a highly regarded woodworking machine that combines precision engineering with user-friendly features, making it an excellent choice for both amateur and professional woodworkers. This model builds on its predecessor’s successful design but introduces several enhancements that elevate its performance and capabilities.

One of the standout features of the DX20i MkII is its robust construction, which utilizes high-quality materials, offering durability and stability during operation. The machine’s cast iron table and heavy-duty cast aluminum body ensure that it can withstand rigorous use without compromising accuracy. This design results in less vibration, allowing for cleaner cuts and finer finish work.

The DX20i MkII is equipped with an upgraded dust extraction system, significantly improving the cleanliness of the workspace and enhancing the machine's efficiency. By effectively capturing dust and debris, users can maintain a safer working environment while minimizing cleanup time.

Another highlight is the advanced digital control panel, which features an intuitive interface that simplifies operation and setup. Users can easily adjust settings, monitor performance, and switch between operating modes with minimal effort. The machine also includes programmable settings, allowing users to store specific configurations for repeated tasks, which increases productivity.

Precision is at the forefront of the DX20i MkII’s design. It incorporates high-performance blades and an adjustable fence system that ensures straight and accurate cuts, crucial for detailed woodworking projects. The cutting head can be tilted for beveled cuts, and the depth of cut is easily adjustable, providing versatility for various wood types and thicknesses.

The DX20i MkII also offers enhanced safety features, including an emergency stop button and blade guards, which provide peace of mind for operators. The machine’s comprehensive user manual provides clear guidelines on setup and safety protocols, making it accessible for those new to woodworking.

Versatile, powerful, and thoughtfully designed, the Charnwood DX20i MkII is an investment that promises to elevate any woodworking workshop. Its blend of advanced technology, robust construction, and user-friendly features ensures that it meets the diverse needs of modern woodworkers, whether they are tackling intricate craftsmanship or larger production runs. With the DX20i MkII, precision woodworking is at your fingertips, ready to bring your creative visions to life.