FMI FVF30PW, FVF24PW, FVF18PW installation manual Safety Information

Page 2

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED PROPANE/LP GAS LOG HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.To prevent performance problems, the use of a propane/LP tank of less than 100 lbs. capacity is not recommended.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance (see Installing Damper Clamp Accessory for Vented Operation, page 10).

6.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

7.If fireplace has glass doors, never op- erate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace open- ing has vents at the bottom, you must open the vents before operating heater.

8.This log heater is designed to be smoke- less. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

9.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 20.

10.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

11.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 17 through 19.

12.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

2

105194

Image 2
Contents What to do if YOU Smell GAS Save this manual for future referenceSafety Information Local Codes Product FeaturesRemote Control Accessories UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Minimum Fireplace Clearance to Combustible Materials InstallationCheck GAS Type LOG Sizing RequirementsIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace FloorChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Items Included for Installation Installing GWMS2 Optional Wall Mounted SwitchInstalling Logs Connecting to Log SetLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Burner Primary AIR Holes Inspecting BurnersPilot Flame Pattern Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Maintenance,Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsTechnical Service AccessoriesService Hints SpecificationsIllustrated Parts Breakdown Heat Majic LOG Models FVF18PW, FVF24PW, FVF30PWParts List KEY Part Number for FVF18PW FVF24PW FVF30PW Description QTYWarranty Information Limited Warranty VENT-FREE PROPANE/LP GAS LOG Heaters

FVF18PW, FVF30PW, FVF24PW specifications

The FMI FVF18PW, FVF30PW, and FVF24PW are part of a premier line of electric fireplaces, expertly designed to merge efficiency, luxury, and convenience. Each model boasts distinct features tailored to meet varying needs, making them ideal choices for homeowners seeking a stylish, modern heating solution.

The FMI FVF18PW is a compact yet powerful fireplace, providing an elegant ambiance to smaller spaces. Its sleek design is complemented by a high-efficiency heating system that allows for rapid warming. Utilizing advanced LED technology, the FVF18PW offers realistic flame effects, recreating the allure of a traditional fire without the associated hassles. This model includes several user-friendly controls, enabling you to customize the flame brightness and heat settings, ensuring both comfort and energy savings.

Moving on to the FMI FVF24PW, this model strikes a perfect balance between size and efficiency. Ideal for medium-sized rooms, the FVF24PW features an impressive heat output paired with a stunning visual display. One remarkable characteristic of this unit is its built-in thermostat, which helps maintain consistent temperatures while optimizing energy consumption. The flame effects can be modified to suit your mood, offering a range of colors and intensities, transforming your living space into a cozy retreat.

At the top of this exceptional line, the FMI FVF30PW is a robust fireplace engineered for larger areas, providing significant heat output without compromising on style. This model incorporates innovative heating technologies, including an advanced fan system that distributes warmth evenly throughout the room. The FVF30PW also features customizable flame settings, allowing users to create their desired atmosphere, whether for a relaxing evening or a festive gathering. Additionally, the unit comes with a remote control, enhancing convenience by allowing you to adjust features from anywhere in the room.

Across the FVF series, safety is a paramount concern. Each model is equipped with automatic shut-off features and overheat protection mechanisms for peace of mind. These electric fireplaces are also energy-efficient, providing warmth without the emissions associated with traditional wood-burning options.

In summary, the FMI FVF18PW, FVF30PW, and FVF24PW electric fireplaces combine state-of-the-art technology with beautiful design, bringing warmth, ambiance, and safety to your home. Whether you opt for the compact elegance of the FVF18PW, the versatile allure of the FVF24PW, or the powerful efficiency of the FVF30PW, each model offers a unique solution tailored to enhance your living space.