FMI FVF30PW, FVF24PW, FVF18PW installation manual Cleaning and Maintenance, Replacement Parts

Page 20

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED PROPANE/LP GAS LOG HEATER

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 27). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

INJECTOR HOLDER AND PILOT AIR INLET HOLE

Burner

Injector Holder (May Be Brass

REPLACEMENT PARTS

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will cre-

Tube

or Aluminum Depending on Model)

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

ate soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a quali- fied service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 26).

3.Blow air through the ports/slots and holes in the burner.

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 26 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet

Hole

Figure 27 - Pilot Inlet Air Hole

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-866-672-6040. When calling, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incor- porated at 1-866-672-6040 for referral in- formation. When calling, have ready

model number of your heater

the replacement part number

20

105194

Image 20
Contents What to do if YOU Smell GAS Save this manual for future referenceSafety Information Product Features Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeMinimum Fireplace Clearance to Combustible Materials LOG Sizing RequirementsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace FloorChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing GWMS2 Optional Wall Mounted Switch Installing LogsItems Included for Installation Connecting to Log SetLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Maintenance,Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsAccessories Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Heat Majic LOG Models FVF18PW, FVF24PW, FVF30PWParts List KEY Part Number for FVF18PW FVF24PW FVF30PW Description QTYWarranty Information Limited Warranty VENT-FREE PROPANE/LP GAS LOG Heaters

FVF18PW, FVF30PW, FVF24PW specifications

The FMI FVF18PW, FVF30PW, and FVF24PW are part of a premier line of electric fireplaces, expertly designed to merge efficiency, luxury, and convenience. Each model boasts distinct features tailored to meet varying needs, making them ideal choices for homeowners seeking a stylish, modern heating solution.

The FMI FVF18PW is a compact yet powerful fireplace, providing an elegant ambiance to smaller spaces. Its sleek design is complemented by a high-efficiency heating system that allows for rapid warming. Utilizing advanced LED technology, the FVF18PW offers realistic flame effects, recreating the allure of a traditional fire without the associated hassles. This model includes several user-friendly controls, enabling you to customize the flame brightness and heat settings, ensuring both comfort and energy savings.

Moving on to the FMI FVF24PW, this model strikes a perfect balance between size and efficiency. Ideal for medium-sized rooms, the FVF24PW features an impressive heat output paired with a stunning visual display. One remarkable characteristic of this unit is its built-in thermostat, which helps maintain consistent temperatures while optimizing energy consumption. The flame effects can be modified to suit your mood, offering a range of colors and intensities, transforming your living space into a cozy retreat.

At the top of this exceptional line, the FMI FVF30PW is a robust fireplace engineered for larger areas, providing significant heat output without compromising on style. This model incorporates innovative heating technologies, including an advanced fan system that distributes warmth evenly throughout the room. The FVF30PW also features customizable flame settings, allowing users to create their desired atmosphere, whether for a relaxing evening or a festive gathering. Additionally, the unit comes with a remote control, enhancing convenience by allowing you to adjust features from anywhere in the room.

Across the FVF series, safety is a paramount concern. Each model is equipped with automatic shut-off features and overheat protection mechanisms for peace of mind. These electric fireplaces are also energy-efficient, providing warmth without the emissions associated with traditional wood-burning options.

In summary, the FMI FVF18PW, FVF30PW, and FVF24PW electric fireplaces combine state-of-the-art technology with beautiful design, bringing warmth, ambiance, and safety to your home. Whether you opt for the compact elegance of the FVF18PW, the versatile allure of the FVF24PW, or the powerful efficiency of the FVF30PW, each model offers a unique solution tailored to enhance your living space.