Burley G4121 mk2 warranty General Requirements

Page 3

3.GENERAL REQUIREMENTS

3.1Gas appliances must be installed in accordance with the rules in force. In the UK it is the law that all gas appliances must be installed by a CORGI registered installer, in accordance with the Gas Safety (Installation and Use) regulations (as amended). The installation must also be in accordance with the relevant parts of local and national building regulations and in accordance with BS5871 pt4 except where Burley instruction state differently. For the Republic of Ireland, reference should be made to IS813 and ICP3 and any guidance notes from Bord Gais. Failure to have the fire fitted by a qualified person nullifies ALL guarantees.

3.2The space to be heated must have a wall vent of at least 100cm² of ventilation and an openable window or patio door. The vent must be positioned at least 1 metre away from the appliance. A vent may have been supplied with the appliance and this is the preferred type although it is possible to use alternatives.

3.3In the Republic of Ireland two vents of not less than 60cm² each, one not less than 1.6m above the other, must be installed in the room.

3.4When providing ventilator openings consideration must be given to the avoidance of locations where discomfort from draughts may cause the user to block the openings. Similarly the possibility of curtains or furniture blocking ventilation openings must be considered. Floor vents, closable window vents or chimneys are not suitable means of ventilation.

3.5Working surfaces include the air outlet grille.

3.6The heater must not be used in a room area of less than 40m3 in volume. To convert cubic feet (ft³) to cubic metre (m³) divide the room volume in cubic feet by 35.3. Adjoining spaces, not separated by a door may be combined.

3.7The heater must not be used on or against a combustible surface.

3.8No furniture, soft furnishings, decorations, wall coverings or curtains must be within 1 metre of the appliance and its convection outlets.

3.9The heater must not be installed in high rise flats or basements.

3.10Do not install this appliance in:

a)A bathroom, shower room or in a room used or intended to be used as sleeping

accommodation. Sleeping areas must be separated from the appliance by a door.

b)In a cupboard or compartment within such a room; or

c)In a cupboard, compartment or space adjacent to such a room if there is an air vent from

the cupboard, compartment or space into such a room.

3.11When the heater is not to be used for a time, ensure the gas control or adjacent isolators are turned off.

3.12Using this appliance as a sole heat source can lead to condensation problems in periods of cold weather and heavy use. Always ensure that the room has a background heat source such as central heating or storage heaters.

3.13The fire must not be run with its door open or with cracked, incorrectly fitted or missing glass.

3.14The glass door acts as a guard on the appliance to prevent risk of fire or injury from burns and no part of it may be permanently removed. It does not give full protection for young children, the elderly or infirm. Parts of the appliance get hot, an additional guard to BS6539 or BS6778 must be used in the presence of children, the elderly and infirm.

3.15This is not a drying appliance. Do not place clothing or other articles, on or against it.

3.16On no account must air inlets under the stove or outlet grills (see diagram below) be obstructed.

3.17Do not store or use flammable substances on or near the heater.

3.18Do not spray aerosols on or near the heater when it is working.

3

Image 3
Contents For the following countries GB, IE Leave These Instructions with the UserRefer to Rating Label I2H I3P Appliance DataUnpacking the Appliance IntroductionGeneral Requirements Hearths, floor protection and carpets Clearance to Walls Gas SupplySiting the Appliance LOG Layout LPG Propane Laying the LogsCommissioning the Appliance LOG Layout Natural GASFireguards Lighting the HeaterSpark Failure ThermostatOxygen Depletion Pilot System Instructing the CustomerServicing Instructions Accessories General Requirements User InstructionsControls Lighting ProcedureGeneral Turn OFF Procedure

G4121 mk2 specifications

The Burley G4121 mk2 is a cutting-edge bicycle that exemplifies the fusion of performance, comfort, and durability. Built for both novice and experienced riders, this model reflects Burley's commitment to engineering excellence and innovative design.

One of the standout features of the G4121 mk2 is its lightweight aluminum frame. This construction material not only contributes to the bike's overall agility but also enhances its resistance to corrosion and wear. The geometry of the frame is meticulously designed to provide an optimal balance between speed and stability, making it ideal for various terrains, from urban roads to light trails.

Equipped with a Shimano 21-speed transmission, the Burley G4121 mk2 offers riders the versatility needed to tackle steep climbs or swift descents effortlessly. The smooth shifting mechanism ensures precise gear changes, allowing riders to maintain momentum without sacrificing control. This model also features a reliable braking system, incorporating both front and rear disc brakes, which provide excellent stopping power and responsiveness, crucial for navigating through dynamic environments.

Comfort is a key aspect of the G4121 mk2. The bike is fitted with an ergonomic saddle and adjustable handlebars, accommodating different riding styles and preferences. Puncture-resistant tires enhance safety and offer peace of mind during longer rides, minimizing the risk of being stranded due to flat tires.

Incorporating advanced technologies, the G4121 mk2 boasts a lightweight, adjustable suspension system. This feature absorbs shocks from uneven surfaces, ensuring a smoother ride and reducing fatigue during extended journeys. Additionally, the bike’s reflective elements improve visibility in low-light conditions, enhancing safety for commuters and weekend adventurers alike.

The Burley G4121 mk2 also considers practicality with its integrated mounts for racks and fenders, allowing riders to customize their bike for commuting or touring experiences.

In conclusion, the Burley G4121 mk2 stands out not just for its performance characteristics but also for its thoughtful design aimed at enhancing rider experience. It is a versatile bicycle that successfully caters to both form and function, making it a popular choice among cycling enthusiasts.