EMI CAC manual Figure #4

Page 15

START -UP FOR WALL THERMOSTAT CONTROL

7.To check the operation of the condensate pump remove an adjacent ceiling tile to access the condensate pump access:

Insert a squeeze water bottle nozzle through the opening in the condensate pump access panel and fill drain pan. Refer to Figure #4.

Figure #4

Adding water will activate the float switch and the pump. Water must flow regular-

ly with condensate pump energized. If water does not, check the pipe slope or see if there are any pipe restrictions.

8.Ensure that all covers, panels and fil- ters are in place and discharge louvers are correctly positioned.

9.Turn the system power on and set the cooling mode to the lowest thermostat set point to run the compressor.

NOTE: The unit is equipped with a safety switch that will activate the pump when the condensate reaches a critical level. The safety switch will also de-energize the compressor if the water level becomes too high.

10.Repeat the above procedure for all Cassettes in the same systems.

CAC Cassette Evaporator

15

www.enviromaster.com

Image 15
Contents Nominal Circuit Capacities INSTALLATION, Operation and Maintenance ManualTo the Installer Safety InstructionsCAC Cassette High Efficiency Evaporator Standard Features Product DescriptionSystem Options CAC Cassette Controls and Components Preparation for InstallationSmall Unit Shown Medium Unit ShownLarge Unit CAC Cassette Preparation and Positioning PISTON/ORIFICE Installation InstructionCeiling opening Mounting the CAC Cassette Ceiling EvaporatorMAX CAC Cassette Chassis Positioning and InstallationCondensate Piping Correct IncorrectPiping DO’S and DON’TS Pipe Installation Notes Refrigeration PipingUse of a larger line can harm Compressor Assembly Instructions CAC Cassette Evaporator Fascia Installation InstructionsCAC Cassette Evaporator Installation Instructions Electrical WiringMake sure power is off Low Volt Interconnect Wiring High Volt Electrical WiringStart -UP for Wall Thermostat Control LOW Voltage Interconnect WiringFigure #4 Refrigerant Processing Important Notes CAC Cassette Evaporator Test Unit Performance Data Test Unit Performance Data SheetMaintenance and Troubleshooting Procedure Power Supply Check Troubleshooting ProcedureLow Volt Controls Cooling Only UnitsElectric Heat How long will the fan run? Frequently Asked QuestionsCAC Performance Data Discharge AIR VolumeSmall Cabinet CAC 9,000 12,000 CAC Cassette DimensionsMedium Cabinet CAC 18,000 24,000 Large Cabinet CAC 30,000 36,000 CAC Cassette System Matches CAC Electrical SpecificationsT2C, T3C & T4C Top Discharge Enviromaster International LLC ALL Product Limited WarrantyT2C, T3C & T4C 2, 3 & 4 Zone Top Discharge EMI’S High Efficiency Product LineHigh Wall Evaporator S1C & S1H Single Zone S2C Dual Zone

CAC specifications

EMI CAC, or Electromagnetic Interference Common-mode Current, is a critical concern in electronic device design and operation. It refers to the unwanted electromagnetic energy that can disrupt the normal functioning of electronic circuits, particularly in complex systems. EMI can arise from various sources, including power lines, radio frequency transmitters, and even other components within the same device.

One of the main features of EMI CAC is its dual nature. It can be both a source of interference and a metric to assess the integrity of electronic systems. The impacts of EMI are far-reaching, affecting communication signals, power supply reliability, and overall device performance. As technology progresses and devices become more compact, the likelihood of EMI issues increases, making it essential for engineers to develop effective solutions.

Several technologies are employed to mitigate EMI CAC in electronic systems. Shielding is one of the most common methods, involving the use of conductive materials to block electromagnetic fields. This can take the form of metal enclosures or coatings that prevent the escape of emissions. Another strategy involves the use of filters, such as ferrite beads and capacitors, which can suppress common-mode currents before they enter the sensitive parts of a circuit.

The characteristics of EMI CAC vary depending on several factors, including frequency, amplitude, and the specific environment in which the electronic devices operate. High-frequency EMI is particularly challenging due to its ability to penetrate enclosures and disrupt signals. Additionally, common-mode noise can often appear in differential signals, exacerbating the situation and making detection more difficult.

Achieving EMC (Electromagnetic Compatibility) is a major goal for designers dealing with EMI CAC. This involves not only reducing emissions from devices but also improving their immunity to external sources of interference. Effective grounding techniques and careful layout planning are crucial in minimizing EMI effects.

In summary, EMI CAC represents a significant challenge in modern electronics, with a need for advanced solutions to ensure device performance and reliability. By understanding its features, employing effective technologies for mitigation, and addressing its characteristics, engineers can create robust designs that thrive in the increasingly complex electromagnetic landscape of today’s technological world.