Emerson MSP422 manual Setting the Bottom Reference, Setting 4 mA and 20 mA Levels

Page 24

Mobrey MSP422

Reference Manual

IP2013, Rev BA

February 2012

Setting the Bottom Reference

Screen display:

b.rEF

Defaults:

8.000 (m), 26.24 (ft.), 314.9 (in.)

NOTE:

See Figure 4-1 on page 4-3 for a map of the programming menu structure and how to access all the menu options.

To change the bottom reference (b.rEF) setting:

a)If entering the menu system from the PV display, press the green button to indicate the “b.rEF” menu option (see above note.)

b)Press the blue button to enter the menu for b.rEF. The display indicates the present b.rEF value.

c)If this value is correct, press the red button , and then press the green button to get to the next menu option.

d)Press the blue button to start editing. The first digit flashes to indicate it can be edited.

e)Press the green button repeatedly to edit the flashing digit.

f)Press the blue button to move to the next digit. The digit flashes to indicate it can be edited.

g)Repeat steps (e) and (f) until the last digit is flashing, and edited as required.

h)Press the blue button to confirm the new b.rEF value. None of the digits should now be flashing.

i)If the new value is correct, press the red button to save. The display changes to the next menu option.

j)If the new value is incorrect, press the blue button to exit to the menu. The “b.rEFre-appears; re-start at step (b) or press for the next menu.

Setting 4 mA and 20 mA Levels

Screen display:

4 and 20

4mA level defaults:

0.000 (m), 00.00 (ft.), 000.0 (in.)

20mA level defaults:

7.500 (m), 24.60 (ft.), 295.2 (in.)

The 4 mA level may be set above, or below, the 20 mA level to suit the monitoring or control equipment.

NOTE:

To set the 4 and 20 mA levels by ranging the transmitter to a fixed target, such as the level in the tank at any particular time, skip these menu options by pressing the green button twice to get to the next menu option.

NOTE:

See Figure 4-1 on page 4-3 for a map of the programming menu structure and how to access all the menu options.

To change the 4 mA value:

a)If entering the menu system from the PV display, press the green button repeatedly until the “4” menu option is indicated (see above note.)

b)Press the blue button to enter the menu for the 4 mA level. The display indicates the present value of the 4 mA level.

4-6

Image 24
Contents Mobrey MSP422 Reference ManualPage Mobrey MSP422 Ultrasonic Liquid Level Transmitter Page Table of Contents Service Troubleshooting Appendix a Reference DataAppendix B Product Certifications Safety Messages Section IntroductionManual Overview Customer Support ProductRECYCLING/DISPOSAL Transmitter Overview Components of the TransmitterMSP422 Features Components of the TransmitterSection Installation Before YOU Install General ConsiderationsGuidelines Mechanical Installation Mounting ConsiderationsLiquid Surface Conditions In-tank Effects Min And Max Distances From Tank WallProcedure Mounting the Transmitter Above the Liquid SurfacePtfe Electrical Installation After Completing the WiringCabling the Transmitter Lightning / Surge Protection and Other Loop Devices Section Starting upPower Up Before Programming OverviewImportant notes to help you program the transmitter MSP422 Menu Map MSP422 Menu MapProgramming the MSP422 Display UnitsFirst Measurements Bottom ReferenceSetting the Bottom Reference Setting 4 mA and 20 mA LevelsSetting the Output Damping Selecting the Action on Alarm Condition HoldSetting 4 mA and 20 mA Levels Using Ranging Screen displayLearn About Echoes From False Targets Final Checks Power Failure Mobrey MSP422 Service and Troubleshooting Diagnostics for the MSP422 General Troubleshooting Error MessagesServicing Specifications Appendix a Reference DataA-1 A-2Temperature and Pressure Ratings Load LimitationsDimension Drawings Figure A-4. The 2-in. NPT/BSPT mounting bracket Appendix B Product Certifications Avoid contact with leads and terminalsManufacturing Location European Union Directive Information NON-HAZARDOUS Location CertificationsAmerican and Canadian Certifications Page Emerson Process Management Rosemount Measurement

MSP422 specifications

The Emerson MSP422 is an advanced multi-sensor platform designed for various industrial applications, providing crucial data insights for efficient operations. This innovative device integrates multiple measurement technologies, including temperature, pressure, and humidity sensors, into a single unit, making it an ideal choice for monitoring diverse environments and processes.

One of the key features of the MSP422 is its robust design, tailored for industrial applications. The unit is built to withstand harsh conditions, including extreme temperatures and moisture levels, ensuring reliable performance even in challenging environments. Its durability makes it suitable for industries such as oil and gas, chemical processing, and pharmaceuticals.

The MSP422 stands out with its high precision and accuracy across all its sensor capabilities. The temperature sensor operates within a wide range, offering precise readings essential for maintaining optimal operational conditions. Similarly, the pressure measurements are finely tuned, providing critical insights for process control and safety monitoring.

Connectivity is another major advantage of the MSP422. Equipped with advanced communication protocols, it facilitates seamless integration with existing industrial systems. Users can easily connect the MSP422 to their industrial automation systems, enabling real-time data transmission and allowing for timely decision-making. The device supports protocols like Modbus, making it versatile for various applications.

The MSP422 is also designed with user-friendly interfaces, including customizable dashboards and data visualization tools. This feature enhances the user experience, allowing operators to easily monitor parameters and analyze data trends over time. The intuitive interface reduces the learning curve, enabling quick adaptation in dynamic industrial environments.

Power management is another critical characteristic of the MSP422. It is designed for low power consumption, which is essential for minimizing operational costs and extending the lifespan of the device. The platform can operate on various power sources, providing flexibility in deployment across diverse sites.

In summary, the Emerson MSP422 is a leading multi-sensor platform that brings together precision measurement, rugged design, connectivity, user-friendly interfaces, and efficient power management. Its versatile features make it an essential asset for industries seeking to enhance monitoring, improve efficiency, and maintain safety in their operations.