To change from the default action of Hold:

a)If entering the menu system from the PV display, press the green button repeatedly until the “AL” menu option is indicated (see above note.)

b)Press the blue button to enter the menu “AL”. The display indicates the present action setting.

c)If this action is correct, press the red button and then the green button to get to the next menu option.

d)Press the blue button to start editing. The action flashes to indicate it can be edited.

e)Press the green button repeatedly to scroll through the actions.

f)Press the blue button to confirm an action. The flashing then stops.

g)If the new action is correct, press the red button to save. The display changes to the next menu option.

h)If the new action is incorrect, press the blue button to exit to the menu. The “ALre-appears; re-start at step (b) or press for the next menu.

Setting 4 mA and 20 mA Levels Using Ranging

Screen display:

S--4 and S-20

NOTE:

If the 4 and 20 mA levels are programmed as described above, this menu can

be skipped; it overwrites previously entered data for them. Press the

green button to get to the final menu option, “Lrn”.

This is for setting the 4 mA or 20 mA levels by ranging the instrument to a known target, e.g. the present level in a vessel.

NOTE:

See Figure 4-1 on page 4-3 for a map of the programming menu structure and how to access all the menu options.

To change the 4 mA level:

a)If entering the menu system from the PV display, press the green button repeatedly until the S--4 menu option is indicated (see above note.)

b)Ensure the target is the 4 mA level and, with the display indicating that level, press the blue button .

c)The display indicates the present 4 mA level setting, not the new level reading. If this setting is correct, press the red button and then the green button to get to the next menu option.

d)Press the blue button to start editing. The display flashes alternately “4” and the new level reading.

e)Press the blue button to confirm the new level reading is the new 4 mA level.

f)If the new 4 mA level is correct, press the red button to save. The display changes to the next menu option.

g)If the new 4 mA level is incorrect, press the blue button to exit to the menu. The menu option S--4 re-appears; re-start at step (b) or press for the next menu option.

4-9

Image 27
Contents Reference Manual Mobrey MSP422Page Mobrey MSP422 Ultrasonic Liquid Level Transmitter Page Table of Contents Service Troubleshooting Appendix a Reference DataAppendix B Product Certifications Section Introduction Safety MessagesManual Overview Customer Support ProductRECYCLING/DISPOSAL Components of the Transmitter Transmitter OverviewComponents of the Transmitter MSP422 FeaturesSection Installation Before YOU Install General ConsiderationsGuidelines Mounting Considerations Mechanical InstallationMin And Max Distances From Tank Wall Liquid Surface Conditions In-tank EffectsMounting the Transmitter Above the Liquid Surface ProcedurePtfe Electrical Installation After Completing the WiringCabling the Transmitter Lightning / Surge Protection and Other Loop Devices Starting up SectionPower Up Before Programming OverviewImportant notes to help you program the transmitter MSP422 Menu Map MSP422 Menu MapDisplay Units Programming the MSP422Bottom Reference First MeasurementsSetting 4 mA and 20 mA Levels Setting the Bottom ReferenceSetting the Output Damping Hold Selecting the Action on Alarm ConditionScreen display Setting 4 mA and 20 mA Levels Using RangingLearn About Echoes From False Targets Final Checks Power Failure Mobrey MSP422 Service and Troubleshooting Diagnostics for the MSP422 General Troubleshooting Error MessagesServicing A-2 SpecificationsAppendix a Reference Data A-1Load Limitations Temperature and Pressure RatingsDimension Drawings Figure A-4. The 2-in. NPT/BSPT mounting bracket Avoid contact with leads and terminals Appendix B Product CertificationsManufacturing Location European Union Directive Information NON-HAZARDOUS Location CertificationsAmerican and Canadian Certifications Page Emerson Process Management Rosemount Measurement

MSP422 specifications

The Emerson MSP422 is an advanced multi-sensor platform designed for various industrial applications, providing crucial data insights for efficient operations. This innovative device integrates multiple measurement technologies, including temperature, pressure, and humidity sensors, into a single unit, making it an ideal choice for monitoring diverse environments and processes.

One of the key features of the MSP422 is its robust design, tailored for industrial applications. The unit is built to withstand harsh conditions, including extreme temperatures and moisture levels, ensuring reliable performance even in challenging environments. Its durability makes it suitable for industries such as oil and gas, chemical processing, and pharmaceuticals.

The MSP422 stands out with its high precision and accuracy across all its sensor capabilities. The temperature sensor operates within a wide range, offering precise readings essential for maintaining optimal operational conditions. Similarly, the pressure measurements are finely tuned, providing critical insights for process control and safety monitoring.

Connectivity is another major advantage of the MSP422. Equipped with advanced communication protocols, it facilitates seamless integration with existing industrial systems. Users can easily connect the MSP422 to their industrial automation systems, enabling real-time data transmission and allowing for timely decision-making. The device supports protocols like Modbus, making it versatile for various applications.

The MSP422 is also designed with user-friendly interfaces, including customizable dashboards and data visualization tools. This feature enhances the user experience, allowing operators to easily monitor parameters and analyze data trends over time. The intuitive interface reduces the learning curve, enabling quick adaptation in dynamic industrial environments.

Power management is another critical characteristic of the MSP422. It is designed for low power consumption, which is essential for minimizing operational costs and extending the lifespan of the device. The platform can operate on various power sources, providing flexibility in deployment across diverse sites.

In summary, the Emerson MSP422 is a leading multi-sensor platform that brings together precision measurement, rugged design, connectivity, user-friendly interfaces, and efficient power management. Its versatile features make it an essential asset for industries seeking to enhance monitoring, improve efficiency, and maintain safety in their operations.