Kidde PI9000CA manual LED Indicators, Smoke Sensing Chamber Operation

Page 13

Operation

LED Indicators

This smoke alarm is equipped with a red LED indicator. The red LED is located under the test button and has several modes of operation.

Standby Condition The red LED will flash every 30–40 seconds to indicate that the smoke alarm is operating properly.

Alarm Condition When the alarm senses particles of combustion and goes into alarm, the red LED will flash rapidly (once every two seconds). The rapid flashing LED and temporal alarm will continue until the air is cleared.

Hush Condition The red LED will flash every 2 seconds as long as the alarm is in Hush® mode.

Low Battery Condition The red LED will be accompanied by an audible chirp. Replace the battery when this condition occurs.

Alarm Memory

This smoke alarm is equipped with an

 

alarm memory feature which produces

 

a rapid chirping sound when the test

 

button is pushed. This sound indicates

 

that the alarm has been activated

 

since it was last tested. Releasing

 

the test button clears the memory.

 

If the alarm memory sound is heard,

 

release the test button and press the

 

test button again to enter the normal

 

test mode.

Smoke Sensing Chamber Operation

The alarm will “chirp” if any of the components in the smoke sensing chamber fail. This chirp will occur between the flashes of the red LED indicator light. If the “chirp” occurs at the same time as the red LED flash, see Battery Replacement section for more information.

12

Image 13
Contents Dual Sensor Introduction ContentsInstallation Recommended Locations Image 1A Image 1B Locations to Avoid Ceilingminimum Mounting Mobile HomesRemove Testing Battery Operation Hush Control Feature Alarm Tamper-Resist Feature Smoke Sensing Chamber Operation LED IndicatorsAlarm Removal MaintenanceCleaning the Alarm Limitations of Smoke Alarms Fire SafetyGood Safety Habits NRC Information What To Do When The Alarm SoundsAdditional Recommendations Year Limited Warranty Warranty