First Alert SCO7 General Limitations of SMOKE/CO Alarms, Troubleshooting Guide, Limited Warranty

Page 7

GENERAL LIMITATIONS OF SMOKE/CO ALARMS

This Smoke/CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for Carbon Monoxide Alarms must be met. The Smoke Alarm portion of this device is not intended to alert hearing impaired resi- dents. Special purpose Smoke Alarms should be installed for hearing impaired residents (CO Alarms are not yet available for the hearing impaired).

Smoke/CO Alarms may not waken all individuals. Practice the escape plan at least twice a year, making sure that everyone is involved – from kids to grandparents. Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping. If children or others do not readily waken to the sound of the Smoke/CO Alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them in fire drill and in the event of an emergency. It is recommended that you hold a fire drill while family members are sleeping in order to determine their response to the sound of the Smoke/CO Alarm while sleeping and to determine whether they may need assistance in the event of an emergency.

Smoke/CO Alarms cannot work without power. Battery operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units.

This Smoke/CO Alarm will not sense smoke or CO that does not reach the sensors. It will only sense smoke or CO at the sensor. Smoke or CO may be present in other areas. Doors or other obstructions may affect the rate at which CO or smoke reaches the sensors. If bedroom doors are usually closed at night, we recommend you install an alarm device (Combination CO and Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them.

This Smoke/CO Alarm may not sense smoke or CO on another level of the home. Example: This alarm device, installed on the second floor, may not sense smoke or CO in the basement. For this reason, one alarm device may

not give adequate early warning. Recommended minimum protection is one alarm device in every sleeping area, every bedroom, and on every level of your home. Some experts recommend battery powered Smoke and CO Alarms be used in conjunction with interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms” for details.

Smoke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This Smoke/CO Alarm is not intended for people who are hearing impaired.

The Alarm may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas.

This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns against increasing CO levels or the presence of smoke, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives. Homeowners and renters must still insure their lives.

This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test this device weekly. The unit should be replaced immediately if it is not operating properly.

This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning of the source of smoke or CO is in a remote part of the home, away from the alarm device.

TROUBLESHOOTING GUIDE

 

 

 

If the Alarm...

Problem...

You should...

 

 

 

 

 

 

 

 

 

Horn "chirps" about once per minute;

Low battery warning.

Install two new AA batteries*.

Voice: "Replace battery in [Location]" every 5 hours

 

 

 

 

 

 

 

 

 

 

 

Horn does three rapid "chirps" every minute;

Device is not working properly, and needs to be

Units under warranty should be returned to

Voice: "Detector error in [Location, example

replaced.

manufacturer for replacement. See “Limited

"Kitchen"], please see manual" repeated every 5

 

Warranty” for details.

hours; LED has 3 rapid flashes with "chirps".

 

 

 

 

 

 

 

 

Carbon Monoxide Alarm ONLY:

 

 

CO Alarm goes back into alarm 4 minutes after you

CO levels indicate a potentially dangerous situation.

IF YOU ARE FEELING SYMPTOMS OF CO

Silence it.

 

POISONING, EVACUATE your home and call 911

 

 

or the Fire Department. Refer to "If The CO Alarm

 

 

Sounds" for details.

 

 

 

 

 

 

CO Alarm sounds frequently even though no high

The CO Alarm may be improperly located. Refer to

Relocate your Alarm. If frequent alarms continue,

levels of CO are revealed in an investigation.

“Where to Install This Alarm” for details.

have home rechecked for potential CO problems.

 

 

You may be experiencing an intermittent CO

 

 

problem.

 

 

 

 

 

 

Smoke Alarm ONLY:

 

 

Smoke Alarm sounds when no smoke is visible.

Unwanted alarm may be caused by non-emergency

Silence Alarm using remote control or manual

 

source like cooking smoke.

button; clean the Alarm’s cover with a soft, clean

 

 

cloth. If frequent unwanted alarms continue, relocate

 

 

your Alarm. Alarm may be too close to a kitchen,

 

 

cooking appliance, or steamy bathroom.

 

 

 

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)

LIMITED WARRANTY

BRK Brands, Inc., ("BRK") the maker of First Alert® brand products warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling. 303 Nelson Avenue, Neosho, MO 64850-8806.

Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.

For your records, please record:

Date Purchased: _________________ Where Purchased: ___________________________

First Alert® is a registered trademark of the First Alert Trust.

Printed in Mexico M08-0048-005 Q 06/06

7

Image 7
Contents Introduction Table of ContentsStep by Step Guide to Programming this Alarm USER’S ManualAvoiding Dead AIR Spaces InstallationWhere to Install this Alarm Where this Alarm should not be InstalledIf the CO Alarm Sounds If Your SMOKE/CO Alarm SoundsHOW to Install this Alarm What to do FIRST-IDENTIFY the Type of AlarmUsing the Silence Features Weekly TestingRegular Maintenance If the Smoke Alarm SoundsWhat YOU Need to Know about CO Regulatory Information for SMOKE/CO AlarmsHOW can I Protect MY Family from CO POISONING? Special Compliance Considerations About Smoke AlarmsInstalling Smoke Alarms in Mobile Homes Agency Placement RecommendationsTroubleshooting Guide General Limitations of SMOKE/CO AlarmsLimited Warranty

SCO7 specifications

The First Alert SCO7 is an advanced smoke and carbon monoxide detector that combines safety and technology in a compact design. This combination alarm is engineered to effectively sense both smoke from fires and harmful carbon monoxide gas, making it an essential device for modern households.

One of the standout features of the SCO7 is its ability to provide dual protection. It utilizes an ionization smoke sensor that is particularly effective at detecting fast-flaming fires, alongside an electrochemical carbon monoxide sensor that offers precise and reliable CO detection. This dual capability ensures that users are alerted to multiple dangers, enhancing overall safety.

The SCO7 is also equipped with a voice alarm system. Unlike traditional alarms that merely beep, the SCO7 announces the type of danger present, whether it be smoke or carbon monoxide. This feature allows occupants to quickly assess the situation and react appropriately, which is critical in emergency scenarios.

Another important characteristic of the First Alert SCO7 is its ease of installation and maintenance. The device is powered by a combination of AC power and battery backup, ensuring functionality even during power outages. Furthermore, it includes a convenient tamper-resistant battery compartment that prevents unauthorized removal, making it an ideal choice for families with children.

The SCO7 also features a sleek design, allowing it to blend seamlessly into various home décors. Its compact size makes it easy to mount on walls or ceilings without drawing attention away from the surroundings. Additionally, the unit is equipped with a test/silence button, making it simple for users to conduct routine checks to ensure the unit is functioning correctly.

The technology within the First Alert SCO7 adheres to strict safety guidelines, with the unit being rigorously tested to meet UL standards. It's an investment in peace of mind, providing comprehensive protection from two of the most significant dangers present in homes today. Overall, the First Alert SCO7 stands out in its ability to combine multiple safety features, user-friendly design, and reliance on advanced technology, making it a top choice for anyone looking to enhance their home safety measures.