Message

Causes

Corrective Actions

 

 

 

Caution!

NVRAM_CLR jumper is

Move the NVRAM_CLR

NVRAM_CLR jumper

installed in the clear

jumper to the default position

is installed on

setting. CMOS has been

(pins 3 and 5). See Figure 6-1

system

cleared.

for jumper location. Restart

board.Please run

 

the system and re-enter the

SETUP.

 

BIOS settings. See "Using the

 

 

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 35.

 

 

 

CPU set to

The processor speed may

If not an intentional setting,

minimum

be intentionally set lower

check other system messages

frequency.

for power conservation.

for possible causes.

 

 

 

Current boot mode

The system failed to boot

Ensure that the boot mode is

is set to UEFI.

because UEFI boot mode is

set correctly and that the

Please ensure

enabled in BIOS and the

proper bootable media is

compatible

boot operating system is

available. See "Using the

bootable media is

non-UEFI.

System Setup Program and

available. Use

 

UEFI Boot Manager" on

the system setup

 

page 35.

program to change

 

 

the boot mode as

 

 

needed.

 

 

 

 

 

Decreasing

Faulty or improperly

Reseat the memory modules.

available

installed memory modules. See "Troubleshooting System

memory.

 

Memory" on page 113.

 

 

 

Embedded NICx and

The operating system NIC

Check the system

NICy:

interface is set in BIOS.

management software or the

OS NIC=<ENABLED

The Management Shared

System Setup program for

DISABLED>,

NIC interface is set in

NIC settings. If a problem is

Management

management tools.

indicated, see

Shared NIC=

 

"Troubleshooting a NIC" on

<ENABLED

 

page 107.

DISABLED>

 

 

22

About Your System

Page 22
Image 22