Dell T110 owner manual By the power supplies Boots without this warning, Troubleshooting System

Models: T110

1 144
Download 144 pages 30.26 Kb
Page 32
Image 32

Message

Causes

Corrective Actions

 

 

 

Warning! Power

The system configuration

If any system components

required exceeds

of the processor, memory

were just upgraded, return the

PSU wattage.

modules, and expansion

system to the previous

Check PSU and

cards may not be supported

configuration. If the system

system

by the power supplies.

boots without this warning,

configuration.

 

then the replaced

Warning!

 

component(s) are not

 

supported with this power

Performance

 

 

supply. See "Power Supply" on

degraded. CPU and

 

 

page 93.

memory set to

 

 

 

minimum

 

 

frequencies to

 

 

meet PSU wattage.

 

 

System will

 

 

reboot.

 

 

 

 

 

Warning!

Invalid memory

Ensure that the memory

Unsupported

configuration. The system

modules are installed in a valid

memory

will run but with reduced

configuration. See "General

configuration

functionality.

Memory Module Installation

detected. The

 

Guidelines" on page 80. If the

memory

 

problem persists, see

configuration is

 

"Troubleshooting System

not optimal. The

 

Memory" on page 113.

recommended

 

 

memory

 

 

configuration

 

 

is: <message>.

 

 

Write fault.

Write fault on selected drive.

Faulty USB device, USB medium, optical drive assembly, hard drive, or hard-drive subsystem.

Replace the USB medium or device. Ensure that the USB or SATA cables are properly connected. See "Troubleshooting a USB Device" on page 106 and "Troubleshooting a Hard Drive" on page 117.

NOTE: For the full name of an abbreviation or acronym used in this table, see "Glossary" on page 131.

32

About Your System

Page 32
Image 32
Dell T110 By the power supplies Boots without this warning, Will run but with reduced Configuration. See General