Message

Causes

Corrective Actions

 

 

 

Memory odd/even

Faulty or improperly

See "Troubleshooting System

logic failure at

installed memory modules. Memory" on page 113.

address, read

 

 

value expecting

 

 

value.

 

 

 

 

 

Memory

Faulty or improperly

See "Troubleshooting System

write/read

installed memory modules. Memory" on page 113.

failure at

 

 

address, read

 

 

value expecting

 

 

value.

 

 

 

 

 

Memory set to

The memory frequency

If not an intentional setting,

minimum

may be intentionally set

check any other system

frequency.

lower for power

messages for possible causes.

 

conservation.

 

 

The current memory

Ensure that your memory

 

configuration may support

configuration supports the

 

only the minimum

higher frequency. See "General

 

frequency.

Memory Module Installation

 

 

Guidelines" on page 80.

 

 

 

Memory tests

POST memory test was

Information only.

terminated by

terminated by pressing the

 

keystroke.

spacebar.

 

 

 

 

MEMTEST lane

Invalid memory

Ensure that the memory

failure

configuration. A

modules are installed in a valid

detected on x.

mismatched memory

configuration. See "General

 

module is installed.

Memory Module Installation

Guidelines" on page 80.

About Your System

25

Page 25
Image 25
Dell T110 Memory frequency If not an intentional setting, May be intentionally set Check any other system, Lower for power