BRK electronic CO5120B user manual Where not to Install CO Alarms, Do not locate this CO alarm

Page 8

WHERE NOT TO INSTALL CO ALARMS

DO NOT locate this CO alarm:

In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or greasy areas.

Within 5 feet of any cooking appliance. The alarm should be between 5 and 20 feet from any cooking appliance.

Closer than 20 feet from a furnace or other fuel burning heat source, or fuel burning appliances like a water heater.

In extremely humid areas. This alarm should be at least 10 feet from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other source of high humidity.

In areas where temperature is colder than 40˚F (4˚C) or hotter than 100˚F (38˚C). These areas include unconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.

In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air returns, or open windows. Blowing air may prevent CO from reaching the sensors.

In direct sunlight.

WARNING!

This CO alarm is designed for use inside a single-family home or apartment. It is not meant to be used in common lobbies, hallways, or basements of multi-family buildings unless working CO alarms are also installed in each family living unit. CO alarms in common areas may not be heard from inside individual family living units.

WARNING!

This CO alarm alone is not a suitable substitute for complete detection systems in places which house many people, like hotels or dormitories, unless a CO alarm is also placed in each unit.

WARNING!

DO NOT use this CO alarm in warehouses, industrial or commercial buildings, special- purpose non-residential buildings, RVs, boats, or airplanes. This CO alarm is specifically designed for residential use, and may not provide adequate protection in non- residential applications.

7

Image 8
Contents 120VAC 60 Hz .085A Standby .087A Alarm Model CO5120B-User’s ManualTable of Contents Basic Safety Information IntroductionHOW Your CO Alarm Works Cover Of Your CO AlarmGeneral Information Malfunction WarningBasic Operation CO Alarm Specifications Supply Voltage 120VAC 60Hz .085A Standby .087A AlarmInstallation Where to Install CO AlarmsA Single-level Home A Multi-level HomeWhere not to Install CO Alarms Do not locate this CO alarmUsing the Optional Locking Features Battery Compartment LockTo Unlock the Battery Compartment Mounting Bracket Lock Tools you will needHOW to Install Your CO Alarm Before you begin installationActivating the battery back-up Parts Of This CO AlarmSINGLE-STATION Installation AC powered CO alarms will not operate Interconnecting Multiple CO AlarmsInterconnecting Multiple CO Alarms To Install Do not remove or disconnect the alarm If Your CO Alarm SoundsIf the Alarm Sounds If the CO alarm...remains silent Using the Silence FeatureFinding the Source of CO After an Alarm Interconnected Alarms Latching Alarm IndicatorNon-Interconnected or Stand-Alone Alarm Testing and Maintenance Weekly TestingRegular Maintenance To keep the CO alarm in good working orderWhat You Need To Know About CO What is CO?Symptoms of CO Poisoning Potential Sources Of CO Home How Can I Protect My Family? Underwriters Laboratories Inc. UL2034 What Levels of CO Cause an Alarm?UL2034 Required Alarm Points Troubleshooting Guide If your CO alarm does this It means You shouldUnderstanding the Light and Horn Patterns AC Power on During TestingUnderstanding the Light and Horn Patterns AC Power OFF General Limitations Of CO Alarms Page Page Limited Warranty

CO5120B specifications

The BRK electronic CO5120B is a state-of-the-art carbon monoxide detector that serves as an essential safety device for households and commercial spaces. Designed with advanced technologies and features, the CO5120B ensures reliable detection of carbon monoxide, a colorless and odorless gas that can be extremely harmful or even fatal.

One of the standout features of the CO5120B is its electrochemical sensor, which is both sensitive and accurate in detecting low levels of carbon monoxide. This technology not only enhances the unit's reliability but also ensures a quicker response time in the event of a CO leak. The detector has a measurement range of 30 to 999 parts per million (PPM), allowing it to monitor a wide range of potential threat levels.

The CO5120B also comes equipped with a digital display that shows real-time CO levels, providing users with instant information about the air quality in their environment. This feature is particularly beneficial as it enables users to assess potential risks immediately and take necessary actions before escalating issues occur. The display also features a peak level memory that records the highest level of carbon monoxide detected since the last reset, aiding in diagnosing potential problems over time.

Battery backup is another critical characteristic of the CO5120B. With a 9V battery backup option, the unit continues to provide protection even during power outages, ensuring that families and occupants remain safe under any circumstances. Meanwhile, an end-of-life signal alerts users when it's time to replace the detector, ensuring long-term effective monitoring.

The CO5120B is designed with a low-profile, sleek look, allowing it to blend seamlessly into any home decor. Its simple installation process requires minimal tools, making it accessible for DIY enthusiasts and everyday users alike. The device is also equipped with an easy-to-access test/reset button, allowing users to routinely check the functionality of the unit.

Overall, the BRK electronic CO5120B is a reliable and efficient carbon monoxide detector that prioritizes safety and user-friendliness. Its combination of cutting-edge sensor technology, real-time monitoring, battery backup, and added convenience features makes it an excellent choice for anyone looking to enhance their safety against this silent threat in the home or workplace.