Interconnected units must meet ALL of the following requirements:

A maximum of 18 units total may be interconnected. (See page 13 for details.)

The same fuse or circuit breaker must power all interconnected units.

The total length of wire interconnecting the units should be less than 1000 feet. The interconnect wire should be Type 18 gauge AWM or larger, rated at least 300V.

If an interconnect wire is not already part of your household wiring, you will need to install one.

Failure to meet any of the above requirements could damage the units and cause them to malfunction, removing your protection.

TO INSTALL:

1.Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.

2.Strip off about 1/2” of the plastic coating on the violet interconnect wire on the power connector.

3.Using wire nuts, connect the power connector to the AC power.

• Connect the white wire on the power connector to the neu- tral wire in the junction box.

• Connect the black wire on the power connector to the hot wire in the junction box.

• Connect the violet wire on the power connector to the inter- connect wire in the junction box. Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the violet interconnect wire.

4. Plug the power connector into the back of the CO alarm.

5. Position the base of the alarm over the mounting bracket and turn. The alarm

can be positioned over the bracket every 60°. Turn the

unit clockwise (right) until the unit is in place.

DANGER!

ELECTRICAL SHOCK HAZARD. Do not restore power until all CO alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.

15

Image 16
Contents 120VAC 60 Hz .085A Standby .087A Alarm Model CO5120B-User’s ManualTable of Contents Basic Safety Information IntroductionHOW Your CO Alarm Works Cover Of Your CO AlarmGeneral Information Malfunction WarningBasic Operation CO Alarm Specifications Supply Voltage 120VAC 60Hz .085A Standby .087A AlarmInstallation Where to Install CO AlarmsA Single-level Home A Multi-level HomeWhere not to Install CO Alarms Do not locate this CO alarmUsing the Optional Locking Features Battery Compartment LockTo Unlock the Battery Compartment Mounting Bracket Lock Tools you will needHOW to Install Your CO Alarm Before you begin installationActivating the battery back-up Parts Of This CO AlarmSINGLE-STATION Installation Interconnecting Multiple CO Alarms Interconnecting Multiple CO AlarmsAC powered CO alarms will not operate To Install If the Alarm Sounds If Your CO Alarm SoundsDo not remove or disconnect the alarm Finding the Source of CO After an Alarm Using the Silence FeatureIf the CO alarm...remains silent Non-Interconnected or Stand-Alone Alarm Latching Alarm IndicatorInterconnected Alarms Testing and Maintenance Weekly TestingRegular Maintenance To keep the CO alarm in good working orderSymptoms of CO Poisoning What is CO?What You Need To Know About CO Potential Sources Of CO Home How Can I Protect My Family? UL2034 Required Alarm Points What Levels of CO Cause an Alarm?Underwriters Laboratories Inc. UL2034 Troubleshooting Guide If your CO alarm does this It means You shouldUnderstanding the Light and Horn Patterns AC Power on During TestingUnderstanding the Light and Horn Patterns AC Power OFF General Limitations Of CO Alarms Page Page Limited Warranty

CO5120B specifications

The BRK electronic CO5120B is a state-of-the-art carbon monoxide detector that serves as an essential safety device for households and commercial spaces. Designed with advanced technologies and features, the CO5120B ensures reliable detection of carbon monoxide, a colorless and odorless gas that can be extremely harmful or even fatal.

One of the standout features of the CO5120B is its electrochemical sensor, which is both sensitive and accurate in detecting low levels of carbon monoxide. This technology not only enhances the unit's reliability but also ensures a quicker response time in the event of a CO leak. The detector has a measurement range of 30 to 999 parts per million (PPM), allowing it to monitor a wide range of potential threat levels.

The CO5120B also comes equipped with a digital display that shows real-time CO levels, providing users with instant information about the air quality in their environment. This feature is particularly beneficial as it enables users to assess potential risks immediately and take necessary actions before escalating issues occur. The display also features a peak level memory that records the highest level of carbon monoxide detected since the last reset, aiding in diagnosing potential problems over time.

Battery backup is another critical characteristic of the CO5120B. With a 9V battery backup option, the unit continues to provide protection even during power outages, ensuring that families and occupants remain safe under any circumstances. Meanwhile, an end-of-life signal alerts users when it's time to replace the detector, ensuring long-term effective monitoring.

The CO5120B is designed with a low-profile, sleek look, allowing it to blend seamlessly into any home decor. Its simple installation process requires minimal tools, making it accessible for DIY enthusiasts and everyday users alike. The device is also equipped with an easy-to-access test/reset button, allowing users to routinely check the functionality of the unit.

Overall, the BRK electronic CO5120B is a reliable and efficient carbon monoxide detector that prioritizes safety and user-friendliness. Its combination of cutting-edge sensor technology, real-time monitoring, battery backup, and added convenience features makes it an excellent choice for anyone looking to enhance their safety against this silent threat in the home or workplace.