Task 009: Installing Voice/Data w/Filter 66-Block Connections

2. BitStorm 1900 Installation and Testing

Task 009: Installing Voice/Data w/Filter 66-Block Connections

Use this procedure to connect the BitStorm 1900 to the EtherLoop cross-connect in applications where voice/data service is required with a Filter 66-Block.

Requirements

This procedure requires the following tools and materials:

5 BitStorm 1900 cable harnesses

5 intermediate cables

Cross-connect block(s) of the same type used in the existing main distribution frame (MDF)

Cross-connect punch-down tool

Jumper Wire (24 AWG)

"Appendix B. Cabling Specifications," on page 115 contains the complete specifications for the cables and wiring required in this procedure.

Step Procedure

1.) Mount 66-blocks on wall in an appropriate area for running jumpers.

2.) Verify the room position on frame blocks.

3.) Replace jumpers to 66-Filter Block and retest phone lines.

4.) Refer to Figure 2-14, "Voice/Data Filter 66-Block Connections for 10306 CO Modems," on page 65, and Figure 2-15, "Voice/Data Filter 66-Block Connections for 10224 CO Modems," on page 66.

2-64

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00