2. BitStorm 1900 Installation and Testing

Step Procedure

1.) Select and apply grounded anti-static protection.

WARNING: ELECTROSTATIC DISCHARGE! Anti-static protection required! The BitStorm 1900 shelves are shipped with the circuit packs installed. When handling any circuit pack, you must wear grounded anti-static protection. The discharge of static electricity can damage the circuit packs.

2.)

!

3.)

Select the mounting point in the bay where the top holes of the shelf mounting flanges will be attached.

WARNING: POSSIBLE EQUIPMENT DAMAGE! Installa- tion Requirement! For a single-shelf application without a Fan Tray, be sure to leave at least three inches of space above and below the BitStorm 1900 shelves to dissipate heat.

Align the holes of the shelf mounting flanges with the mounting holes in the bay as shown in Figure 2-5, "BitStorm 1900 Modem Shelves Mounted in Bay."

1900-A2-GN20-00

BitStorm 1900 Installation and Maintenance Guide