Task 007: Installing the Data Network Connection with an MIU

2. BitStorm 1900 Installation and Testing

Task 007: Installing the Data Network Connection with an MIU

Use this procedure to connect the BitStorm 1900 to the Ethernet data network using an MIU.

Requirements

This procedure requires the following:

Ethernet data network installed

Serial cable and DB9S to RJ-11 serial adapter (included)

PC with serial port to configure system

Two Category 5 crossover or straight cables terminated with RJ-45 connectors according to Table 2-1.

Table 2-1: Data Cable Selection for MIU Shelf Processor

MIU

Cable Requirements

 

Application

 

 

 

 

 

 

 

 

 

RS-232

RJ-11 cable (a DB9S to

 

To a PC (for configura-

 

RJ-11 serial adapter is

 

tion only)

 

included)

 

 

 

 

 

 

 

Ethernet Pass Thru

50-pin connector decapus

 

To Ethernet switch

 

cable (DB50F) part #

 

 

 

 

04-00017-01, with 10

 

 

 

 

RJ-45 cables (included)

 

 

 

 

 

 

 

10 Base-T X (top port)

RJ-45 straight cable, 6’

 

To a port on an interme-

 

(included)

 

diate switch or hub

(Management ports

 

 

 

 

 

 

NOTE: Switch or hub must

must be connected)

 

 

 

 

 

have connection to

 

 

 

EtherLoop network

 

 

 

router.

 

 

 

 

 

 

 

 

 

10 Base-T (bottom port)

Not used in this release

 

Not used in this release

 

 

 

 

 

Step Procedure

1.) Connect one end of the RJ-45 (crossed) cable to the switch/router, then route the other end to the 10 Base T-X port of MIU.

2-54

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Page 70
Image 70
Paradyne 1900 manual Task 007 Installing the Data Network Connection with an MIU, Step Procedure, Requirements