Paradyne 1900 manual Step Procedure, continued, Power

Models: 1900

1 160
Download 160 pages 57.32 Kb
Page 66
Image 66
Power

2. BitStorm 1900 Installation and Testing

Step Procedure

(continued)

 

 

3.)

!

With the power supply turned OFF, connect the -48 V DC (260W) or 110 V AC (260W) power source according to the following table and Figure 2-8, "Typical DC Power Harness Connection to -48 V DC (260W) Power Source," on page 51.

WARNING: POSSIBLE EQUIPMENT DAMAGE! With the -48 V DC power supply, reversed polarities on the power feed can irreparably damage the BitStorm 1900 shelf components. Be certain that power feeds are connected properly to the power source, with the red lead connected to the -48 V DC supply (negative terminal) as shown in the table below. Note that this is the opposite of other (non-telecommunications) applications, in which the red lead is usually connected to the positive (+) terminal.

Power

Power Source

Terminal Connection

Line Fuse

Lead

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

-48

V DC supply

Negative (-)

10 AMP, 260W

 

 

 

 

 

Black

-48

V DC return

Positive (+)

 

 

 

 

 

N/A

110 V AC supply

IEC

6 AMP, 260W

 

 

 

 

 

2-50

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Page 66
Image 66
Paradyne 1900 manual Step Procedure, continued, Power