Current Poll Interval, and Set Trap Targets

2. BitStorm 1900 Installation and Testing

Step Procedure

(continued)

 

 

14.) From this screen changes to the Community Name,

Current Poll Interval, and Set Trap Targets

can be made. Refer to the following table as a guide for these settings. If there are no changes, press <Enter> to continue to the next item.

Setting

 

Description

 

 

 

 

Community Name

The Community Name is used by SNMP V1

 

as a minimum security control tool much like a user

 

ID and/or password.

 

For this field, enter an identifier of up to 15 alpha

 

characters.

 

 

Current Poll Interval

The Current Polling Interval

 

provides the ability to set the poll interval in number

 

of seconds. The SNMP Agent polls the modems

 

every n seconds for trap conditions (alarms).

 

(n=how often the equipment is polled.)

 

The acceptable range is 5 to 60 seconds

 

 

(inclusive).

 

To disable the polling, set the poll interval to 0.

 

 

Set Trap Targets

Set Trap Targets is used to set the IP

 

Address of the Network Management Stations

 

where the SNMP Traps are designated to.

 

Up to 3 Trap Targets can be set.

 

 

 

2-94

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00