Task 012: Configuring the MIU

2. BitStorm 1900 Installation and Testing

Task 012: Configuring the MIU

Complete the following steps to configure the MIU.

Step Procedure

1.) Ensure that the BitStorm 1900 is powered on.

2.) Verify the PC has an ASCII terminal emulator loaded (i.e., Hyperterminal software, etc.).

3.) Connect the PC to the MIU card using the MIU Craft Cable (RS-232 to RJ-11 adapter and telephone cable) as shown in Figure 2-18, "Craft Connection with the MIU Craft Cable," on page 73.

a.) Connect the DB-9 end of the cable to the serial COM port on the PC.

b.) Connect the RJ-11 connector to the RS-232 jack on the MIU card.

2-72

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Page 88
Image 88