1. BitStorm 1900 IP DSLAM
10 Mbps CO Modem Card Specifications
2. BitStorm 1900 Installation and Testing
WAN Interface Card Specifications
Power Card Specifications
Appendix A. Installation Requirements
3. BitStorm 1900 Maintenance
Maintenance Guidelines
Maintenance Checklists
Appendix C. Craft Interface Screens
Appendix B. Cabling Specifications
List of Figures
Figure 2-21 Voice/Data System Test Points
List of Tables
List of Tables
BitStorm 1900 Installation and Maintenance Guide
viii
1900-A2-GN20-00
About This Document
1900-A2-GZ40, BitStorm 1900 EMI Gasket Installation Procedures
Focus and Audience
Related Documents
08-01019-01, StormTracker - Spectrum Manager User Guide
Conventions
ENTER, Name, Tab, programs\seven\aa1
About This Document
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
Introduction
1. BitStorm 1900 IP DSLAM
Product Overview
The BitStorm 1900 System Components
BitStorm 1900 Shelf
Fan Tray
Air Baffle
Filter Shelf Option
Filter 66-Block Option
10306 CO Modem Cards
Filter Shelf
10224 CO Modem Cards
Privacy Management
CO Modem Cards
Enabled
Same Card Broadcast
Feature Function
Disabled
Spectrum Manager-Video Protect
Spectrum Manager ADSL Protect
Passes VLAN Tagged Frames
WAN Interface Cards
MIU SNMP Functionality
MIU Management Interface Card - supports 10306 and 10224 modem cards
StormPort CPE Modems
Mixing CO Modem Cards
Special Features
10 Mbps CO Modem Card Specifications
10306 CO Modem Card
10306 CO Modem Specifications
BitStorm 1900 Installation and Maintenance Guide
Specification
Mandatory, use -48 V DC with 260 W DC power
Table 1-3 System Power Specifications with 10306 CO Modem
10306 CO Modem IP Multicast Operation
Figure 1-3 10306 IP Multicast Operation
BitStorm 1900 Installation and Maintenance Guide
1. BitStorm 1900 IP DSLAM
1-14
The 10306 IP Multicast Operation works in the following manner
The 10224 CO modem card provides 24 statistically multiplexed
10224 CO Modem Card
EtherLoop lines 12 per single 10 Mbps modem
10224 CO Modem Specifications
BitStorm 1900 Installation and Maintenance Guide
Specification
Figure 1-4 BitStorm 1900 with 10224 Modem Cards
Configuration assumes 10 modems cards are used
Table 1-4 System Power Specifications with 10224 CO Modem
BitStorm 1900 Installation and Maintenance Guide
1. BitStorm 1900 IP DSLAM
MIU Management Interface Unit
WAN Interface Card Specifications
MIU CO Modem Specifications
BitStorm 1900 Installation and Maintenance Guide
Specification
Figure 1-5 BitStorm 1900 with MIU 01-00075-01 and 10306 CO Modems
Management Commands
Layer 2/3 Switch
BitStorm 1900 Installation and Maintenance Guide
Hospitality /VBN Carrier
260 W DC
Power Card Specifications
BitStorm 1900 Installation and Maintenance Guide
Figure 1-7 260 W DC Power Card
260 W DC Power Card Specifications
Specification
260 W AC
BitStorm 1900 Installation and Maintenance Guide
Figure 1-8 260 W AC Power Card
260 W AC Power Card Specifications
Specification
Fan Tray 110/220 V AC
Fan Tray Specifications
Table 1-5 Power Specifications for the AC Fan Tray
Table 1-6 Power Specifications for the DC Fan Tray
Fan Tray -48 V DC
Audible Alarm Fan Failure LEDsON/OFF
BitStorm 1900 Installation and Maintenance Guide
Filter Shelf
Low-Pass Filter Specifications
Filter 66-Block
Front Panel Filter 66-Block
BitStorm 1900 Installation and Maintenance Guide
Back Panel
1. BitStorm 1900 IP DSLAM
Table 1-7 BitStorm 1900 Component Requirements
BitStorm 1900 Component Requirements
1. BitStorm 1900 IP DSLAM
BitStorm 1900 Installation and Maintenance Guide
1-32
1900-A2-GN20-00
2. BitStorm 1900 Installation and Testing
Figure 2-1 BitStorm 1900 Installation Flowchart
Installation Flowchart
2. BitStorm 1900 Installation and Testing
BitStorm 1900 Installation and Maintenance Guide
Installing the BitStorm
Installation Task List
Step Procedure
Task 001 Pre-Installation Checklist
Table 2-8 Installation Tools, Equipment, and Materials
Step Procedure
continued
RXKDYHFRPSOHWHGWKLVWDVN
STOP
Step Procedure
Task 002 Installing the 19” Fan Tray
NOTE The power supply for the multiplexer must also be -48 V DC
Step Procedure
continued
Figure 2-2 Fan Tray Mounting
NOTE The power supply for the multiplexer must also be 110/220 V AC
Step Procedure
continued
Figure 2-3 -48 V DC Fan Tray
4. Install the air filter frame a. The filter must be removed
Step Procedure
continued
RXKDYHFRPSOHWHGWKLVWDVN
Task 003 Installing the BS1900 and Filter Shelves
1. Select and apply grounded anti-static protection
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
2. BitStorm 1900 Installation and Testing
Figure 2-5 BitStorm 1900 Modem Shelves Mounted in Bay
Mid-Mount
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 004 Installing the Air Baffle
Requirements
RXKDYHFRPSOHWHGWKLVWDVN
Step Procedure
Task 005 Installing the Circuit Packs
2. BitStorm 1900 Installation and Testing
BitStorm 1900 Installation and Maintenance Guide
Installation Requirements, on page
Task 006 Connecting Power to the Shelf
Step Procedure
NOTE The filter shelf does not require a power feed
Power
Step Procedure
continued
Single Power Source
Step Procedure
Rundant Power Source
Power Supply #1
Figure 2-9 Typical Power Connection to 260W AC Power Source
Step Procedure
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 007 Installing the Data Network Connection with an MIU
2. BitStorm 1900 Installation and Testing
BitStorm 1900 Installation and Maintenance Guide
Layer 2/3 Switch
Step Procedure
2. BitStorm 1900 Installation and Testing
BitStorm 1900 Installation and Maintenance Guide
Ethernet Pass-Thru 10Base T-X This port connects to the switch/router
Step Procedure
continued
Figure 2-11 MIU Card with Cable Connections
2. BitStorm 1900 Installation and Testing
Step Procedure
Task 008 Installing Voice/Data & Filter Shelf
Task 009 Installing Voice/Data w/Filter
Step Procedure
Task 008 Installing Voice/Data & Filter Shelf Connections
This procedure requires the following tools and materials
10 BitStorm 1900 cable harnesses 10 intermediate cables
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
4. Connect one Amp-Champ connector of an intermediate cable to the Line/CPE side of the EtherLoop cross-connect block, then connect the other end to an Amp-Champ to Dual Omni Grid cable
Step Procedure
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 009 Installing Voice/Data w/Filter 66-Block Connections
1. Mount 66-blocks on wall in an appropriate area for running jumpers
2. Verify the room position on frame blocks
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 010 Installing the Data-only Connections
Requirements
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 011 Installing External Voice Switch Connections
Requirements
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
Task 012 Configuring the MIU
Complete the following steps to configure the MIU
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Figure 2-19 COM Port Settings
Step Procedure
continued
The following screen displays requiring a Password to continue
Step Procedure
continued
Step
Procedure
Table 2-3 CLI Command Line Interface Commands
continued
2. BitStorm 1900 Installation and Testing
Table 2-3 CLI Command Line Interface Commands
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
2. BitStorm 1900 Installation and Testing
Table 2-3 CLI Command Line Interface Commands
It is not advised to power down the system in order to perform
a reset of the system
Step Procedure
The BitStorm 1900 MIU Craft Interface Main
2. BitStorm 1900 Installation and Testing
BitStorm 1900 Installation and Maintenance Guide
Configuration Menu will display
Network Interface Configuration screen
Step Procedure
2. BitStorm 1900 Installation and Testing
continued
Step Procedure
13. Enter the current date and time
Step Procedure
User Account Administration
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Step Procedure
key to return to the User Account Administration
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
Ethernet port as shown in Figure 2-20, Telnet Connection for the
Task 013 Configuring Remote Management
BitStorm
Using SNMP Network Management Software
Step Procedure
Using Telnet for Remote Provisioning and Management
1. Initiate a Telnet session
2. Type command in the Open field and click OK. The DOS prompt displays
Step Procedure
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
2. BitStorm 1900 Installation and Testing
Step Procedure
BitStorm 1900 Installation and Maintenance Guide
continued
ifconfig -m 0 and press Enter
Step Procedure
continued
BitStorm 1900 Installation and Maintenance Guide
Procedure
2. BitStorm 1900 Installation and Testing
Step
The Current Polling Interval
Current Poll Interval, and Set Trap Targets
Step Procedure
2. BitStorm 1900 Installation and Testing
continued
Step Procedure
RXKDYHFRPSOHWHGWKLVWDVN
STOP
Step Procedure
Task 014 Testing the BitStorm 1900 Installation
2. BitStorm 1900 Installation and Testing
Step Procedure
Layer 2/3 Switch
BitStorm 1900 Installation and Maintenance Guide
2. BitStorm 1900 Installation and Testing
Step Procedure
Layer 2/3 Switch
BitStorm 1900 Installation and Maintenance Guide
Step Procedure
Task 015 Testing Voice Connectivity
Step Procedure
Task 016 Testing Data Connectivity
Step Procedure
Task 017 EtherLoop End-to-End Testing
NOTE The browser application must be configured for no proxies. Refer to
Step Procedure
continued
RXKDYHFRPSOHWHGWKLVWDVN
Maintenance Guidelines
3. BitStorm 1900 Maintenance
Wiring Conditions
Data Network Equipment Configuration
BitStorm 1900 Equipment Installation
Cable Connections
Equipment Failure
Voice/Data Connectivity Troubleshooting Checklist
Maintenance Checklists
Table 3-1 Voice/Data Connectivity Maintenance in Facility Room
3. BitStorm 1900 Maintenance
Table 3-2 End-to-End Maintenance Checklist
End-to-End Maintenance Checklist
3. BitStorm 1900 Maintenance
See the checklist in Table 3-1, “Voice/Data
Bay Requirements and Specifications
Appendix A. Installation Requirements
BitStorm 1900 Support Equipment
Table A-1 BitStorm 1900 System Specifications
BS1900 System Specifications
Fan Trays
Grounding Environment Specifications
Table A-1 BitStorm 1900 System Specifications continued
IBN Grounding Environment
CBN Grounding Environment
Network Support Equipment
BS1900 Component Installation Requirements
Installation Tools and Materials
Installation Site Requirements
BitStorm 1900 Physical Characteristics
Equipment Location
Table A-4 BitStorm Operational Requirements
Cable Connections and Specifications
Appendix B. Cabling Specifications
Figure B-1 Cabling - Filter Shelf with 10306 Modem Cards
10306 Modem Card Cabling
BitStorm 1900 Installation and Maintenance Guide
Appendix B. Cabling Specifications
Figure B-2 Cabling - Filter 66-Block with 10306 Modem Cards
10306
Figure B-3 Cabling - Filter Shelf with 10224 Modem Cards
10224 Modem Card Cabling
Appendix B. Cabling Specifications
BitStorm 1900 Cable Harness
BitStorm 1900 Installation and Maintenance Guide
Figure B-4 Cabling - Filter 66-Block with 10224 Modem Cards
Appendix B. Cabling Specifications
Decapus Cable
MIU Connector Layer 2/3 Switch Connectors
BitStorm 1900 Installation and Maintenance Guide
Figure B-6 AMP Champ to Dual AMP Champ Cable
AMP-Champ to Dual AMP Champ Cable
Table B-1 AMP-Champ to Dual AMP-Champ Cable Specifications
Figure B-7 AMP Champ to Dual Omni Grid Cable
AMP Champ to Dual Omni Grid Cable
Appendix B. Cabling Specifications
Table B-2 AMP Champ to Dual Omni Grid Cable Specifications
BitStorm 1900 Installation and Maintenance Guide
B-124
Figure B-8 Omni Grid to Dual Omni Grid Cable
Omni Grid to Dual Omni Grid
Appendix B. Cabling Specifications
Table B-3 Omni Grid to Dual Omni Grid Cable Specifications
BitStorm 1900 Installation and Maintenance Guide
Color
Appendix B. Cabling Specifications
Omni Grid to Omni Grid Cable
BitStorm 1900 Installation and Maintenance Guide
Figure B-9 Omni Grid to Omni Grid Cable
Appendix B. Cabling Specifications
Table B-4 Omni Grid to Omni Grid Cable Specifications
BitStorm 1900 Installation and Maintenance Guide
B-128
Intermediate Cable Specifications
Power Connector Terminations
Power Cable Harness
B-131
BitStorm 1900 Installation and Maintenance Guide
Appendix B. Cabling Specifications
B-132
1900-A2-GN20-00
Main Menu
Appendix C. Craft Interface Screens
BitStorm 1900 Installation and Maintenance Guide
Figure C-1 Main Menu
Figure C-2 A. Configuration Configuration Menu
Configuration
Figure C-3 A. Configuration A. Network Interface Configuration
BitStorm 1900 Installation and Maintenance Guide
BitStorm 1900 Installation and Maintenance Guide
Figure C-4 A. Configuration B. SNMP Configuration Menu
Appendix C. Craft Interface Screens
1900-A2-GN20-00
BitStorm 1900 Installation and Maintenance Guide
Figure C-7 A. Configuration C. Set Time-of-Day Clock
Appendix C. Craft Interface Screens
C-136
BitStorm 1900 Installation and Maintenance Guide
Statistics
Figure C-8 B. Statistics Menu
Figure C-9 B. Statistics A. Network Layer Statistics
Figure C-10 B. Statistics B. Physical Layer Statistics Menu
BitStorm 1900 Installation and Maintenance Guide
Appendix C. Craft Interface Screens
C-138
Figure C-13 B. Statistics C. Environment Statistics
BitStorm 1900 Installation and Maintenance Guide
Appendix C. Craft Interface Screens
1900-A2-GN20-00
Figure C-14 B. Statistics D. System Memory Statistics
BitStorm 1900 Installation and Maintenance Guide
Figure C-15 B. Statistics E. Shelf Extent Statistics
Appendix C. Craft Interface Screens
BitStorm 1900 Installation and Maintenance Guide
Figure C-16 B. Statistics F. System Error-Reset Data
Figure C-17 B. Statistics G. Modex Daemon Run Statistics
Appendix C. Craft Interface Screens
Firmware Version Information
User Account Administration
Figure C-19 D. User Account Administration Menu
BitStorm 1900 Installation and Maintenance Guide
C-143
Figure C-23 E. Utilities A. Reset Confirmation
Utilities
BitStorm 1900 Installation and Maintenance Guide
Figure C-22 E. Utilities Menu