Task 010: Installing the Data-only Connections

2. BitStorm 1900 Installation and Testing

Task 010: Installing the Data-only Connections

Use this procedure to connect the BitStorm 1900 to the EtherLoop cross-connect in applications where no voice service is required.

Requirements

This procedure requires the following tools and materials:

5 BitStorm 1900 cable harnesses

5 intermediate cables

Cross-connect block(s) of the same type used in the existing main distribution frame (MDF)

Cross-connect punch-down tool

"Appendix B. Cabling Specifications," on page 115 contains the complete specifications for the cables and wiring required in this procedure.

Step Procedure

1.) Place and secure the dedicated EtherLoop cross-connect on the facility main distribution frame.

2.) Route the Tip/Ring pairs originating from the StormPort/CPE lines to the EtherLoop cross-connect.

3.) Terminate the StormPort /CPE Tip/Ring connections to the EtherLoop cross-connect block. Record the StormPort/CPE Tip/ Ring assignments of the EtherLoop cross-connect according to local office procedures.

4.) Connect one Amp-Champ connector of an intermediate cable to the matching connector on the EtherLoop cross-connect block, then route the other connector to the equipment bay containing the BitStorm 1900.

5.) Connect the J1/J2 split connectors on the cable harness to the matching J1/J2 modem connectors of two adjacent modem cards in the BitStorm 1900 shelf. Refer to Figure 2-16,"Data-only Con- nections on the 66-Block for 10306 CO Modem Cards," on page 68, and/or

1900-A2-GN20-00

BitStorm 1900 Installation and Maintenance Guide

2-67