DMP Electronics XR2400F User Codes, 125 34812, User Code Authority Levels, User Code Level 9 only

Page 13

User Codes

User Code Level: 9 only

Function: Allows you to add, delete, and change a user's (person operating the system) user code or authority level.

There are three characteristics associated with each user code that define its capabilities within the system.

125 34812 7

User Number

User Code

User Level

User Number - Every user is numbered. This number identifies them to the system and can be transmitted to the central station

User Code - Each user also has a 3 to 5 digit number they enter into the keyboard. NOTE: A User Code cannot begin or end with zero, or be in the range of 980 to 989, or be in the range of 1 to 299.

User Names - Each code may also be programmed with the user’s name. Up to 16 characters may be entered.

User Level - The user is also assigned a level of authority (1 to 9) or customized authority by the person administrating the system that determines the functions the user can access.

The following table lists system functions users are allowed to access based on the authority level assigned to their codes.

User Code Authority Levels

M enu O ptions

1

2

3

4

5

6

7

8

9

Sensor Reset

 

Zone Status

 

System Status

Display Events

Alarm Silence

 

System Test

 

 

 

 

 

 

 

Zone Monitor

 

 

 

 

 

 

 

Outputs On/Off

 

 

 

 

 

 

 

 

 

Service Request

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fire Drill

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Service Request is not displayed if it has not been enabled on your system.

User Menu

9

Image 13 Contents
Fire Command Center Silencing an Alarm Users Guide Table of ContentsEmergency Evacuation Plans Fire Command Center About Your Addressable Fire Alarm Control PanelUser Menu Fire Command Center User Options Menu Remote Fire Command CenterFour Function Keys Special Fire Command Center Tones Special Fire Command Center DisplaysFire Command Center User Menu Sensor Reset Alarm SilenceZone Status Outputs On OffTurning the Outputs On and Off Checking the Zone StatusUsing the Test function key Using the System Test FunctionSystem Status System Test125 34812 User CodesUser Code Authority Levels User Code Level 9 onlyAdding User Codes Programming Custom User CodesDeleting User Codes Ambush CodesChanging User Codes User # DeletedSetting the System’s Date and Time Setting the Date and TimeUser Code Level 8 and above Time DAY Date is displayedDisplay Events Using the Display EventsUser Code Change Event Displays About the Display Events SectionZone Event Displays Supervisory Event DisplaysUsing the Drill function key Service RequestFire Drill Starting a Fire DrillVoice Module LT-0560 12/00