Ambush Codes

Your system may be programmed to allow user number one (1) to be an Ambush code. This Ambush code functions identically to a standard code with the exception that it sends a silent alarm to the central station. This silent alarm alerts the operator to a duress situation at the premises and prompts the immediate notification of authorities.

Deleting User Codes

1.Access the User Menu.

2.Press COMMAND until USER CODES? displays.

3.Press any SELECT key. ADD DEL CHG is displayed.

4.Press the SELECT key under DEL to delete a user code from the system. You must have a user code level of 9 or have a custom user code with that authority to be able to delete a user code.

5.At the USER NUMBER: - prompt, enter the user number you want to delete and press COMMAND. The displays changes to

USER # DELETED.

6.The display then changes back to USER NUMBER: - allowing you to delete another user. Press the ARROW key twice to exit the User Menu.

Changing User Codes

1.Access the User Menu.

2.Press the COMMAND key until USER CODES? displays.

3.Press any SELECT key. ADD DEL CHG is displayed.

4.Press the SELECT key under CHG to change a user code.

5.At the USER NUMBER: - prompt, enter the user number to change and press COMMAND.

6.The display changes to CODE NO: * * * * *. Press a SELECT key and enter the new user code. Press COMMAND.

Note: Changing a user code does not change the user number.

7.The display then shows the current user name. Press any top row key to clear. To enter a Custom Name, press the number key above the letter that you wish to enter. Each number key displays three letters. Press the top row select key under the letter you wish to enter. Repeat until entire name is entered.

8.The display changes to LEVEL CUSTOM. Refer to Adding User Codes on the previous page for a description of this prompt.

9.After entering the authority level, the displays shows USER # CHANGED for five seconds followed by USER NUMBER: -. This display allows you to enter another user number to change. Press the ARROW key twice to exit the User Menu.

User Menu

11

Image 15
Contents Fire Command Center Silencing an Alarm Users Guide Table of ContentsEmergency Evacuation Plans About Your Addressable Fire Alarm Control Panel Fire Command CenterUser Menu Fire Command Center Remote Fire Command Center User Options MenuFour Function Keys Special Fire Command Center Tones Special Fire Command Center DisplaysFire Command Center User Menu Sensor Reset Alarm SilenceChecking the Zone Status Outputs On OffZone Status Turning the Outputs On and OffSystem Test Using the System Test FunctionUsing the Test function key System StatusUser Code Level 9 only User Codes125 34812 User Code Authority LevelsAdding User Codes Programming Custom User CodesUser # Deleted Ambush CodesDeleting User Codes Changing User CodesTime DAY Date is displayed Setting the Date and TimeSetting the System’s Date and Time User Code Level 8 and aboveDisplay Events Using the Display EventsSupervisory Event Displays About the Display Events SectionUser Code Change Event Displays Zone Event DisplaysStarting a Fire Drill Service RequestUsing the Drill function key Fire DrillVoice Module LT-0560 12/00

XR2400F specifications

The DMP Electronics XR2400F is an advanced industrial-grade device designed for a wide range of applications, particularly in the fields of automation, control systems, and data acquisition. This highly versatile device stands out for its robust performance, exceptional connectivity options, and innovative technologies that cater to the needs of modern industries.

One of the main features of the XR2400F is its powerful processing capabilities. Equipped with a high-performance microcontroller, it ensures swift data processing and handling. This allows it to manage various tasks simultaneously, making it an ideal choice for applications that require real-time processing and responsiveness. The device supports multiple operating modes, enabling users to customize its functionality based on their specific requirements.

The XR2400F is designed with extensive connectivity options, including Ethernet, USB, and Serial ports. This multi-connectivity feature facilitates easy integration with existing systems and devices, allowing for seamless data exchange and communication. Additionally, it supports various communication protocols, including Modbus and TCP/IP, which broadens its compatibility with other industrial equipment and enhances its interoperability.

One of the standout technologies implemented in the XR2400F is its advanced data acquisition capability. The device is equipped with high-resolution analog-to-digital converters, enabling it to capture and process signals with exceptional accuracy. This is crucial for applications where precise measurements are required, such as environmental monitoring and industrial automation.

Moreover, the XR2400F features an intuitive user interface, which simplifies the configuration and monitoring process. Users can easily navigate through settings and parameters, ensuring efficient operation. The device also supports remote monitoring, allowing users to access data and control functions from anywhere, which is a significant advantage in today's increasingly mobile and connected work environments.

In terms of reliability, the XR2400F is built to withstand harsh industrial conditions. Its rugged design and durable materials ensure that it can operate effectively in demanding environments, including extreme temperatures and humidity levels. This reliability makes it a suitable option for applications in manufacturing, energy, and transportation sectors.

Overall, the DMP Electronics XR2400F is a state-of-the-art device that combines exceptional processing power, extensive connectivity, advanced data acquisition capabilities, and robust reliability. Its versatility and adaptability make it an invaluable tool for industries looking to enhance their automation and control systems, providing a reliable solution for their operational needs.