INSTALLATION PROCEDURE

Ei225EN (Only)

Warning: The CO alarm should be installed by a qualified electrican in accordance with the IEE wiring regulations (BS 7671). Failure to install this alarm correctly may expose the user to shock or fire hazards.

Procedure:

1.Select a location complying with the above advice.

2.Disconnect the AC mains supply from the circuit to be used.

3.Slide off the cover as shown in fig 1. Press gently in the centre to release the catches before sliding upwards.

4.Remove the terminal cover screw and expose the connecting terminals.

5.(a) If the wires are coming directly out from the ceiling/wall locate the wire entry slot over the wires and mark the two mounting screw locations. Screw the unit to the ceiling/wall (ensure screws do not penetrate buried wires. The unit can also be screwed on to a standard recessed junction box if required. Seal the wire exit holes (with silicone or similar) to prevent air draughts preventing the carbon monoxide from reaching the sensor.

(b)If surface wiring is being used, bring the wiring in from either of the vertical sides or the bottom as shown in figure 5. Note surface wiring cannot be brought in from the top as it would be in the way of the cover sliding off and also might allow water to penetrate. Screw the unit to the wall.

16

Image 16
Contents Instructions Contents Read this First What to do When the Alarm Sounds What is Carbon Monoxide ? Carbon Monoxide the Silent KillerSymptoms of Carbon Monoxide Poisoning High levels of CO in a house can be caused byB15584-R0-225EN&220EN-U&C 6/9/07 813 AM What happens when your CO Alarm detects Carbon Monoxide ? Table a Effects of Carbon Monoxide PoisoningNever Ignore the Alarm CO Alarm Memory Where to Place CO Alarms Unsuitable LocationsB15584-R0-225EN&220EN-U&C 6/9/07 813 AM Location in room with a fuel burning appliance Location in rooms with Installing Your Carbon Monoxide Alarms Installation Procedure ProcedureSurface Wiring Ei220EN Only Testing Your CO Alarm Testing with Carbon MonoxideMaintaining Your CO Alarm END of Life How to disconnect and remove the alarmProduct Disposal Limitations of CO Alarms B15584-R0-225EN&220EN-U&C 6/9/07 813 AM HOW to Protect Your Family B15584-R0-225EN&220EN-U&C 6/9/07 813 AM Technical Specification Sensor fault is found Getting the CO Alarm Serviced GuaranteeB15584-R0-225EN&220EN-U&C 6/9/07 813 AM Troubleshooting Alarm does not Work with the Test ButtonAlarm Beeps and Amber Light Flashes Every 40 Seconds Alarm Sounds for no Apparent ReasonTEST/HUSH Button does not Silence Alarms RED and Amber Lights FlashProduct Disposal Ei Electronics