10. TECHNICAL SPECIFICATION
Operating Voltage | : | 230±10% VAC, 50Hz |
Power | : | 1 Watt, (60 mA) |
Power on Indicator | : | Green Light on |
Sensor | : | Electrochemical Sensor |
CO Sensitivity | : Meets BS EN 50291: 2001. | |
|
| Unit operates as per Table B (page 9). |
Electrical Safety | : Complies with relevant sections of EN | |
Electromagnetic | : Complies with BS EN 50270 | |
Compatibility |
|
|
Test/Hush Button | : Checks electronics and horn. | |
|
| When the unit is alarming, after sensing CO, pressing the test/hush button |
|
| will immediately stop the horn (the red light will continue to flash). If CO is |
|
| still present the red light and the horn will turn on again after about 4 |
|
| minutes. The unit can only be silenced once during a CO incident. At 300 |
|
| ppm CO the unit cannot be silenced. (With interconnected units, the hush |
|
| only works on the alarm sensing CO). |
Testing with CO | : The red light flashes (see Table B, page 9) within 10 | |
|
| seconds of the unit detecting CO. |