D2071A Operations & Installation Guide 2.0 Installation

Restoral ZN 9 Exceptions: If a battery is not connected to the D2071A when AC power is connected, the control panel sends a RESTORAL ZN 9 Report to the receiver.

A RESTORAL ZN 9 is also sent after the programmer disconnects from the D2071A.

Charging Circuit

The D2071A charges the battery with a float charge circuit using a maximum charging current of 300 mA. The battery discharge and recharge schedule (Table 5) shows voltages during the discharge and recharge cycles.

Table 5: 12 VDC Battery Discharge and Recharge Schedule

Discharge Cycle

 

13.8 V

FACP battery float voltage

 

11.8 V

 

Battery Trouble Report (TROUBLE ZN 9)

 

8.5 V

Disables all processing and memory functions.

 

 

 

Deep battery discharge can occur below this

 

 

 

level.

 

Recharge Cycle

 

AC on

 

Battery recharging begins

 

 

9.0 V

 

Battery Trouble Report (only if the battery is

 

 

 

 

 

 

 

discharged below 8.5 V)

 

 

13.4 V

 

Battery Restoral Report (RESTORAL ZN 9)

 

 

 

 

 

 

13.8 V

 

Battery charged

 

 

Notes:

 

 

 

1.The source supervised is the battery connected to the D2071A.

2.Actual voltage can vary ±15.

2.7.212 VAC Battery Discharge and Recharge Schedule

Refer to Table 5 for the 2 VAC battery discharge and recharge schedule.

2.8Telephone Connections

2.8.1Telephone Cord Installation

Use a D161 or D162 Phone Cord to connect the primary telephone line to the D2071A Modular Jack ( J1). Use a second D161 or D162 Phone Cord to connect the alternate telephone line to the D2071A Modular Jack

( J2).

For all applications, you must connect separate primary and alternate telephone lines to the D2071A.

2.8.2Location

To prevent the jamming of alarm and other reports, wire and locate the RJ31X or RJ38X jack so normal telephone use is temporarily interrupted while the

communicator transmits data (Figure 8). After installation, confirm the D2071A seizes the line, acquires dial tone, and correctly reports to the receiver.

Figure 8:

RJ31X Wiring

 

 

 

 

2

 

3

1

R1

 

 

4

 

1

 

 

 

 

 

 

 

2

 

 

 

 

3

 

R

 

 

4

 

 

 

 

T

 

 

5

 

 

 

 

 

 

 

6

 

 

 

T1

7

 

 

 

8

 

 

 

 

 

 

1 -

Premises phone

3 -

Full modular phone jack

2 -

RJ31X Module

4 -

Incoming Telco line

2.8.3Telephone Line Supervision

The D2071A monitors both the primary and alternate telephone lines while the communicator is idle by sniffing the line for trouble. Telephone line trouble is line voltage below 10 VDC with a current less than

10 mA. If there is a report waiting to be transmitted, the D2071A does not sniff the telephone lines until the report is transmitted or a communication failure occurs. The D2071A reports a faulted condition on the primary telephone line as a TROUBLE ZN B and the alternate telephone line as a TROUBLE ZONE C.

Each line is sniffed once a minute if both lines are good. If a line is determined to be in trouble, the D2071A steps up the test rate and sniffs once every 10 sec. If the trouble still exists after 15 samples (150 sec), the control panel sends a Trouble Report and activates the buzzer, Phone Fail LED, and Phone Line Trouble Relay (if installed). Refer to Section 2.5 Phone Line Trouble Relay on page 13 for installation instructions.

The buzzer, LED, and relay deactivate after a trouble condition on the telephone line when the receiver acknowledges the Phone Line Trouble Report, or when the line returns to normal. If the D2071A attempts to transmit the Phone Line Trouble Report ten times without acknowledgment from the receiver, a communication failure occurs.

If the D2071A is in communication failure, either the primary and alternate telephone lines must be detected as normal and a report acknowledged by the receiver before the buzzer, LED, and relay deactivate.

Bosch 09/04 74-06200-000-F

1 5

Image 15
Contents Operation & Installation Guide EN Fire Alarm Control PanelContents VDC Battery Discharge TablesMandatory Connections for the Nfpa Overview Mandatory Connections Required MaterialsD2071A Control Panel Assembly Slave Communicator ApplicationsReceiving Equipment Alternate Modular Telephone Jack Initiating Circuit Alarm Relay K6Phone Line Trouble LED Mounting TabsStand-Alone Installation InstallationSlave Communicator Installation Earth Ground Wiring Zone 1, Alarm Initiating CircuitClass a Circuit Parameters Mode Wiring Stand-Alone ApplicationsZones 2 and 3 Supervisory Circuits Slave Communicator ApplicationsClass B Circuit Parameters Initiating Circuit Alarm RelayMode 1 and Mode 2 Restrictions InstallationPhone Line Trouble Relay Primary Power SupplyWiring Use Terminals 1 and 2 for primary power supply connectionsReplacement 24 VDC Battery Discharge and Recharge ScheduleTelephone Connections Notification Cable Tie InstallationCall Routing Call Routing AssignmentsAdhesive Strip Mounting End User Instruction LabelScrew Mounting 2 D2002 Mounting PlateNavigating Handler and Program Records ProgrammingEditing a Record Function KeysData Keys TonesProgram Record Program ModulesEditing the Program Record Special Dialing Characters PriPh#Reset Time Receiver Reports Receiver ReportsCommunications Failure TroubleshootingPhone Line Trouble Buzzer, LED, and Relay Activated Phone Line TroubleProgramming with the D5200 Programmer Trouble Zone E2 24 VDC Mode Connection to Facp Zones ProblemsZone Problems 1 12 VAC Mode Battery and TransformerSpecifications SpecificationsBosch 74-06200-000-F

D2071A specifications

The Bosch Appliances D2071A is an exemplary appliance that enhances everyday cooking and food storage with its premium features and stylish design. This model stands out in the Bosch lineup for its innovative technologies designed to provide optimal performance while ensuring user-friendly operation.

One of the main characteristics of the D2071A is its energy efficiency. Bosch has integrated advanced technologies that comply with the highest energy standards, which not only help reduce electricity bills but also promote environmental sustainability. The appliance operates with minimal energy consumption, making it a great choice for eco-conscious consumers.

The D2071A boasts a sleek and modern design that can seamlessly fit into any kitchen decor. With its stainless steel finish, it offers durability as well as an elegant appearance. The appliance is designed with a seamless integration feature, allowing it to blend in with cabinetry, giving a built-in look that is favored by many homeowners.

In terms of performance, the D2071A features advanced cooling technologies that ensure optimal temperature control and food preservation. With a multi-air flow cooling system, cold air is distributed evenly throughout the fridge and freezer compartments, preventing hot spots that can compromise food quality. This technology ensures that perishables stay fresher for longer periods, minimizing waste.

Another notable feature is the adjustable shelving and storage options. The D2071A includes customizable shelving that can be rearranged to accommodate various food items and containers. This flexibility allows users to maximize storage space, making it easy to store everything from tall bottles to wide platters.

The appliance is equipped with intuitive controls and a user-friendly interface. This allows for easy temperature adjustments and access to various settings that enhance the user experience. Additionally, the D2071A comes with a notification system that alerts users in case of temperature fluctuations, helping to maintain food safety.

Overall, the Bosch Appliances D2071A combines modern design with cutting-edge technology, making it a top choice for individuals looking for a high-quality refrigerator. It successfully merges functionality, efficiency, and style, thus catering to the diverse needs of today’s home cooks and families.