D2071A Operations & Installation Guide 6.0 Troubleshooting

6.5Zones Problems

Table 12: Zone Problems

Zone 1 Alarm Initiating Circuit

Symptom

Solution

 

 

 

 

 

Does not go into

 

Maintain a short between Loop ”A”

 

alarm.

 

(Terminals 6 and 7) and Loop “B”

 

 

 

(Terminals 8 and 9) for at least the

 

 

 

 

 

time programmed in Retard Time.

 

Does not

The circuit must remain normal for at

 

immediately restore

least the time programmed in Reset

 

after an alarm.

Time.

 

Remains in trouble

 

An open or ground on the circuit

 

or alarm with all

 

causes a Trouble Report.

 

devices connected

 

Remove the circuit loops from the

 

to the circuit

 

D2071A and meter them for

 

normal.

 

continuity. There should be no

 

 

 

more than 100 resistance

 

 

 

between the wires that connect to

 

 

 

Terminals 6 and 7 and between

 

 

 

the wires that connect to

 

 

 

Terminals 8 and 9.

 

 

 

With the wires for the circuit

 

 

 

loops still removed from the

 

 

 

D2071A, meter them for

 

 

 

continuity to ground.

 

Zone 2 or 3 Supervisory Circuit

 

 

 

 

Symptom

Solution

 

 

 

 

Remains in trouble

 

Confirm the circuit is wired for the

 

or alarm with all

 

mode you selected in the

 

devices connected

 

Class “B” Mode.

 

to the circuit

 

Copy the program from the

 

normal.

 

D2071A to confirm the Class “B”

 

 

 

Mode is correctly programmed.

 

 

 

An open on the circuits causes a

 

 

 

Trouble Report for Modes 2 and 3,

 

 

 

and an Alarm Report for Mode 1. A

 

 

 

ground can cause an Alarm Report

 

 

 

for Modes 2 and 3.

 

 

 

Remove the circuit loops from the

 

 

 

D2071A and meter them for

 

 

 

continuity. There should be no

 

 

 

more than 100 plus the value of

 

 

 

the resistors in the circuit

 

 

 

between the wires that connect to

 

 

 

Terminals 10 and 11, or between

 

 

 

the wires that connect to

 

 

 

Terminals 11 and 12.

 

 

 

With the wires for the circuit

 

 

 

loops still removed from the

 

 

 

D2071A, meter them for

 

 

 

continuity to ground.

 

 

 

 

 

6.6Trouble Zone 9

A TROUBLE ZN 9 Report tells you there is a problem with the battery when the D2071A is in 12 VAC Mode. It also indicates there is a problem with the power supply in the 24 VDC Mode.

6.6.112 VAC Mode (Battery and Transformer)

When a TROUBLE ZN 9 Report occurs in 12 VAC Mode:

1.Confirm there is at least 12 VAC on Terminals 1 and 2.

2.Ensure the outlet the transformer is plugged into meters between 110 VAC and 120 VAC.

3.Confirm the output for the transformer connected to Terminals 1 and 2 is rated for 12 VAC and at least 20 VA.

4.Disconnect the transformer from Terminals 1 and 2 and meter the battery at Terminals 3 and 4. A fully charged battery should show 13.8 V.

5.Ensure the battery is a 12 V sealed, lead-acid type. It should be rated at 2.3 Ah or 7 Ah or greater, depending on the NFPA classification of the installation.

6.6.224 VDC Mode (Connection to FACP)

When a TROUBLE ZN 9 Report occurs in 24 VDC Mode:

1.Confirm Terminals 1 and 2 have 27.6 VDC.

2.Ensure the earth ground is not connected to Terminal 3.

3.Confirm Terminals 4 and 5 are not connected to a battery.

4.Confirm program item 12 V Mode is set to NO.

2 6

Bosch 09/04 74-06200-000-F

Image 26
Contents EN Fire Alarm Control Panel Operation & Installation GuideContents Mandatory Connections for the Nfpa VDC Battery DischargeTables Overview Required Materials Mandatory ConnectionsReceiving Equipment D2071A Control Panel AssemblySlave Communicator Applications Mounting Tabs Initiating Circuit Alarm Relay K6Phone Line Trouble LED Alternate Modular Telephone JackInstallation Stand-Alone InstallationSlave Communicator Installation Class a Circuit Parameters Earth Ground WiringZone 1, Alarm Initiating Circuit Slave Communicator Applications Wiring Stand-Alone ApplicationsZones 2 and 3 Supervisory Circuits ModeInstallation Initiating Circuit Alarm RelayMode 1 and Mode 2 Restrictions Class B Circuit ParametersUse Terminals 1 and 2 for primary power supply connections Primary Power SupplyWiring Phone Line Trouble Relay24 VDC Battery Discharge and Recharge Schedule ReplacementTelephone Connections Call Routing Assignments Cable Tie InstallationCall Routing Notification2 D2002 Mounting Plate End User Instruction LabelScrew Mounting Adhesive Strip MountingProgramming Navigating Handler and Program RecordsTones Function KeysData Keys Editing a RecordEditing the Program Record Program RecordProgram Modules PriPh# Special Dialing CharactersReset Time Receiver Reports Receiver ReportsPhone Line Trouble TroubleshootingPhone Line Trouble Buzzer, LED, and Relay Activated Communications FailureTrouble Zone E Programming with the D5200 Programmer1 12 VAC Mode Battery and Transformer Zones ProblemsZone Problems 2 24 VDC Mode Connection to FacpSpecifications SpecificationsBosch 74-06200-000-F

D2071A specifications

The Bosch Appliances D2071A is an exemplary appliance that enhances everyday cooking and food storage with its premium features and stylish design. This model stands out in the Bosch lineup for its innovative technologies designed to provide optimal performance while ensuring user-friendly operation.

One of the main characteristics of the D2071A is its energy efficiency. Bosch has integrated advanced technologies that comply with the highest energy standards, which not only help reduce electricity bills but also promote environmental sustainability. The appliance operates with minimal energy consumption, making it a great choice for eco-conscious consumers.

The D2071A boasts a sleek and modern design that can seamlessly fit into any kitchen decor. With its stainless steel finish, it offers durability as well as an elegant appearance. The appliance is designed with a seamless integration feature, allowing it to blend in with cabinetry, giving a built-in look that is favored by many homeowners.

In terms of performance, the D2071A features advanced cooling technologies that ensure optimal temperature control and food preservation. With a multi-air flow cooling system, cold air is distributed evenly throughout the fridge and freezer compartments, preventing hot spots that can compromise food quality. This technology ensures that perishables stay fresher for longer periods, minimizing waste.

Another notable feature is the adjustable shelving and storage options. The D2071A includes customizable shelving that can be rearranged to accommodate various food items and containers. This flexibility allows users to maximize storage space, making it easy to store everything from tall bottles to wide platters.

The appliance is equipped with intuitive controls and a user-friendly interface. This allows for easy temperature adjustments and access to various settings that enhance the user experience. Additionally, the D2071A comes with a notification system that alerts users in case of temperature fluctuations, helping to maintain food safety.

Overall, the Bosch Appliances D2071A combines modern design with cutting-edge technology, making it a top choice for individuals looking for a high-quality refrigerator. It successfully merges functionality, efficiency, and style, thus catering to the diverse needs of today’s home cooks and families.