Bosch Appliances D2071A Phone Line Trouble LED, Mounting Tabs, Alternate Modular Telephone Jack

Page 7

D2071A Operations & Installation Guide 1.0 Overview

Figure 1: D2071A Control Panel

12

7

1

2

3

4

5

6

 

7

 

8

Aromat

 

DS1E-M

 

DC12V

 

AG20134408

 

JAPAN

 

30830 BOTTOM VIEW

 

Aromat

9

DS1E-M

 

DC12V

 

AG20134408

 

JAPAN

 

30830 BOTTOM VIEW

 

11 10

1

-

Terminal strip

7 -

Mounting tab

2 -

Programmer connector (J3)

8 -

Alternate modular telephone jack (J2)

3 -

D2071A Enclosure Cover

9 -

Primary modular telephone jack (J1)

4 - Phone Line Trouble Buzzer

10

- Phone Line Trouble Relay socket (K5)

5

- Phone Line Trouble LED

11

- Initiating Circuit Alarm Relay socket (K6)

6

-

LED hole

12

- Strain relief tab

1.8.5Phone Line Trouble LED

This yellow Phone Line Trouble LED (Item 5 in Figure 1) is visible through the top of the enclosure at the upper right corner (Item 6 in Figure 1). This LED lights when the control panel detects telephone line trouble on either the primary or secondary telephone line, when there is a communication failure, and briefly on powerup.

1.8.6Mounting Tabs

Mounting tabs (Item 7 in Figure 1) are located on each end of the D2071A to provide a way to mount the D2071A with screws. You can also use the adhesive strips to mount the D2071A.

1.8.7Alternate Modular Telephone Jack

The alternate telephone jack (Item 8 in Figure 1) connects the D2071A to an alternate telephone line for transmitting to the receiver. If the D2071A fails to contact the receiver after two attempts on the primary line, it switches to the alternate line.

1.8.8Primary Modular Telephone Jack

The primary telephone jack (Item 9 in Figure 1) connects the D2071A to the primary telephone line for transmitting to the receiver.

1.8.9Phone Line Trouble Relay (K5)

Install a D136 Relay in this socket when using the optional Phone Line Trouble Relay (Item 10 in Figure 1) for Terminals 13 to 15. This relay activates when telephone line trouble is detected on the primary or secondary telephone line, communication failure occurs, and briefly at powerup.

1.8.10Initiating Circuit Alarm Relay (K6)

Install a D136 Relay in this socket when using the optional Initiating Circuit Alarm Relay (Item 11 in Figure 1) for Terminals 16 to 18. This relay activates when the initiating circuit is in an alarm condition.

1.8.11Strain Relief Tab

The strain relief tab (Item 12 in Figure 1) prevents unnecessary strain on the connections to the D2071A. Use the cable tie (included) to secure all wire running from the D2071A to the tab.

Bosch 09/04 74-06200-000-F

7

Image 7
Contents Operation & Installation Guide EN Fire Alarm Control PanelContents Tables VDC Battery DischargeMandatory Connections for the Nfpa Overview Mandatory Connections Required MaterialsSlave Communicator Applications D2071A Control Panel AssemblyReceiving Equipment Alternate Modular Telephone Jack Initiating Circuit Alarm Relay K6Phone Line Trouble LED Mounting TabsStand-Alone Installation InstallationSlave Communicator Installation Zone 1, Alarm Initiating Circuit Earth Ground WiringClass a Circuit Parameters Mode Wiring Stand-Alone ApplicationsZones 2 and 3 Supervisory Circuits Slave Communicator ApplicationsClass B Circuit Parameters Initiating Circuit Alarm RelayMode 1 and Mode 2 Restrictions InstallationPhone Line Trouble Relay Primary Power SupplyWiring Use Terminals 1 and 2 for primary power supply connectionsReplacement 24 VDC Battery Discharge and Recharge ScheduleTelephone Connections Notification Cable Tie InstallationCall Routing Call Routing AssignmentsAdhesive Strip Mounting End User Instruction LabelScrew Mounting 2 D2002 Mounting PlateNavigating Handler and Program Records ProgrammingEditing a Record Function KeysData Keys TonesProgram Modules Program RecordEditing the Program Record Special Dialing Characters PriPh#Reset Time Receiver Reports Receiver ReportsCommunications Failure TroubleshootingPhone Line Trouble Buzzer, LED, and Relay Activated Phone Line TroubleProgramming with the D5200 Programmer Trouble Zone E2 24 VDC Mode Connection to Facp Zones ProblemsZone Problems 1 12 VAC Mode Battery and TransformerSpecifications SpecificationsBosch 74-06200-000-F

D2071A specifications

The Bosch Appliances D2071A is an exemplary appliance that enhances everyday cooking and food storage with its premium features and stylish design. This model stands out in the Bosch lineup for its innovative technologies designed to provide optimal performance while ensuring user-friendly operation.

One of the main characteristics of the D2071A is its energy efficiency. Bosch has integrated advanced technologies that comply with the highest energy standards, which not only help reduce electricity bills but also promote environmental sustainability. The appliance operates with minimal energy consumption, making it a great choice for eco-conscious consumers.

The D2071A boasts a sleek and modern design that can seamlessly fit into any kitchen decor. With its stainless steel finish, it offers durability as well as an elegant appearance. The appliance is designed with a seamless integration feature, allowing it to blend in with cabinetry, giving a built-in look that is favored by many homeowners.

In terms of performance, the D2071A features advanced cooling technologies that ensure optimal temperature control and food preservation. With a multi-air flow cooling system, cold air is distributed evenly throughout the fridge and freezer compartments, preventing hot spots that can compromise food quality. This technology ensures that perishables stay fresher for longer periods, minimizing waste.

Another notable feature is the adjustable shelving and storage options. The D2071A includes customizable shelving that can be rearranged to accommodate various food items and containers. This flexibility allows users to maximize storage space, making it easy to store everything from tall bottles to wide platters.

The appliance is equipped with intuitive controls and a user-friendly interface. This allows for easy temperature adjustments and access to various settings that enhance the user experience. Additionally, the D2071A comes with a notification system that alerts users in case of temperature fluctuations, helping to maintain food safety.

Overall, the Bosch Appliances D2071A combines modern design with cutting-edge technology, making it a top choice for individuals looking for a high-quality refrigerator. It successfully merges functionality, efficiency, and style, thus catering to the diverse needs of today’s home cooks and families.