Bosch Appliances D2071A manual Specifications

Page 27

D2071A Operations & Installation Guide 7.0 Specifications

7.0Specifications

Table 13: Specifications

 

 

 

 

 

 

 

 

 

 

 

 

Power Input

 

12 VAC, 20 VA with 12 VDC battery

 

 

 

 

 

 

 

 

 

24 VDC

 

 

 

 

 

 

 

Operating Current

 

 

Specification

 

 

12 VAC Mode

 

 

24 VAC Mode

 

 

 

 

Idle Current

 

 

29.5 mA

 

 

30.0 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Charging

 

 

51.0 mA

 

 

N/A

 

 

 

 

Alarm with Relay

 

 

50.0 mA or 110 mA

 

61.0 mA or 115 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm without Relay

 

 

31.5 mA or 79.0 mA

 

32.0 mA or 80.0 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone Trouble with Relay

 

 

82.0 mA or 120.0 mA

 

 

84.5 mA or 140 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone Trouble without Relay

 

54.0 mA or 110 mA

 

 

55.5 mA or 110 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm and Trouble with Relay

 

110 mA or 160 mA

 

140 mA or 170 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm and Trouble without Relay

 

55.5 mA or 102 mA

 

 

58.0 mA or 140 mA

 

Minimum Panel

 

12 V Mode: 8.5 VDC

 

 

 

 

 

 

 

Operation Voltage

 

24 V Mode: 11.1 VDC

 

 

 

 

 

 

 

Zone 1 Voltage

 

 

Multi-meter in parallel with normal loop Terminals 6 and 7 (-) and normal loop Terminals 8 and 9 (+).

 

 

 

 

Normal: 1.92 VDC

 

 

 

 

 

 

 

 

 

 

Alarm: 0.3 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open: N/A

 

 

 

 

 

 

 

 

 

 

Response Time: 0.2 to 90 sec, depending on the retard or reset time

 

 

 

Zones 2 and 3

 

Multi-meter in parallel with normal loop Terminals 10 and 11 (ZN 2), 11 and 12 (ZN 3).

Voltages

 

Mode 1

 

 

 

 

 

 

 

 

 

 

Normal: 0.0 VDC

 

 

 

 

 

 

 

 

 

 

Alarm (Open): 1.8 VDC

 

 

 

 

 

 

 

 

 

 

Response time: approximately 2 to 4 sec

 

 

 

 

 

 

Mode 2

 

 

 

 

 

 

 

 

 

 

Normal: 0.0 VDC

 

 

 

 

 

 

 

 

 

 

Alarm (Resist): 1.8 VDC

 

 

 

 

 

 

 

 

 

 

Trouble (Break): 9.3 VDC

 

 

 

 

 

 

 

 

 

 

Response time: approximately 2 to 4 sec

 

 

 

 

 

 

Mode 3

 

 

 

 

 

 

 

 

 

 

Normal: 5.8 VDC

 

 

 

 

 

 

 

 

 

 

Alarm (Closed): 1.7 VDC

 

 

 

 

 

 

 

 

 

 

Trouble (Open): 10.3 VDC

 

 

 

 

 

 

 

 

 

 

Response time: approximately 2 to 4 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone Voltage

 

 

Minimum: 20 VDC

 

 

 

 

 

 

 

 

 

 

Normal: 48 VDC to 52 VDC; 24 VDC to 26 VDC

 

 

 

Operating

 

+32°F to +120°F (0°C to +49°C)

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

Enclosure

 

 

Color: red

 

 

 

 

 

 

 

 

 

 

Size (L x W): 7.8 in. x 4.4 in. (20.0 cm x 11.2 cm) including mounting tabs

 

 

 

Material: non-conductive plastic ABS UL94V-O

 

 

 

Wire

 

Refer to NEC, NFPA 70, Article 760 for wire specifications.

 

 

 

Specifications

 

D1220 Transformer wiring distances:

 

 

 

 

 

 

 

 

 

18 AWG (1.2 mm)

 

250 ft (76.2 m) maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

16 AWG (1.5 mm)

 

374 ft (114 m) maximum

 

 

 

 

 

 

14 AWG (1.8 mm)

 

600 ft (182.9 m) maximum

 

 

 

 

 

 

12 AWG (2.3 mm)

 

1000 ft (304.8 m) maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch 09/04 74-06200-000-F

2 7

Image 27
Contents Operation & Installation Guide EN Fire Alarm Control PanelContents VDC Battery Discharge TablesMandatory Connections for the Nfpa Overview Mandatory Connections Required MaterialsD2071A Control Panel Assembly Slave Communicator ApplicationsReceiving Equipment Alternate Modular Telephone Jack Initiating Circuit Alarm Relay K6Phone Line Trouble LED Mounting TabsStand-Alone Installation InstallationSlave Communicator Installation Earth Ground Wiring Zone 1, Alarm Initiating CircuitClass a Circuit Parameters Mode Wiring Stand-Alone ApplicationsZones 2 and 3 Supervisory Circuits Slave Communicator ApplicationsClass B Circuit Parameters Initiating Circuit Alarm RelayMode 1 and Mode 2 Restrictions InstallationPhone Line Trouble Relay Primary Power SupplyWiring Use Terminals 1 and 2 for primary power supply connectionsReplacement 24 VDC Battery Discharge and Recharge ScheduleTelephone Connections Notification Cable Tie InstallationCall Routing Call Routing AssignmentsAdhesive Strip Mounting End User Instruction LabelScrew Mounting 2 D2002 Mounting PlateNavigating Handler and Program Records ProgrammingEditing a Record Function KeysData Keys TonesProgram Record Program ModulesEditing the Program Record Special Dialing Characters PriPh#Reset Time Receiver Reports Receiver ReportsCommunications Failure TroubleshootingPhone Line Trouble Buzzer, LED, and Relay Activated Phone Line TroubleProgramming with the D5200 Programmer Trouble Zone E2 24 VDC Mode Connection to Facp Zones ProblemsZone Problems 1 12 VAC Mode Battery and TransformerSpecifications SpecificationsBosch 74-06200-000-F

D2071A specifications

The Bosch Appliances D2071A is an exemplary appliance that enhances everyday cooking and food storage with its premium features and stylish design. This model stands out in the Bosch lineup for its innovative technologies designed to provide optimal performance while ensuring user-friendly operation.

One of the main characteristics of the D2071A is its energy efficiency. Bosch has integrated advanced technologies that comply with the highest energy standards, which not only help reduce electricity bills but also promote environmental sustainability. The appliance operates with minimal energy consumption, making it a great choice for eco-conscious consumers.

The D2071A boasts a sleek and modern design that can seamlessly fit into any kitchen decor. With its stainless steel finish, it offers durability as well as an elegant appearance. The appliance is designed with a seamless integration feature, allowing it to blend in with cabinetry, giving a built-in look that is favored by many homeowners.

In terms of performance, the D2071A features advanced cooling technologies that ensure optimal temperature control and food preservation. With a multi-air flow cooling system, cold air is distributed evenly throughout the fridge and freezer compartments, preventing hot spots that can compromise food quality. This technology ensures that perishables stay fresher for longer periods, minimizing waste.

Another notable feature is the adjustable shelving and storage options. The D2071A includes customizable shelving that can be rearranged to accommodate various food items and containers. This flexibility allows users to maximize storage space, making it easy to store everything from tall bottles to wide platters.

The appliance is equipped with intuitive controls and a user-friendly interface. This allows for easy temperature adjustments and access to various settings that enhance the user experience. Additionally, the D2071A comes with a notification system that alerts users in case of temperature fluctuations, helping to maintain food safety.

Overall, the Bosch Appliances D2071A combines modern design with cutting-edge technology, making it a top choice for individuals looking for a high-quality refrigerator. It successfully merges functionality, efficiency, and style, thus catering to the diverse needs of today’s home cooks and families.