Hearth and Home Technologies GBST4336I, GBFL4136I owner manual Listing and Code Approvals

Page 7

1 Listing and Code Approvals

A. Appliance Certification

MODELS: GBST4336I, GBFL4136I

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: B-Vent Gas Appliance

STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007

This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Altitudes”.

May be installed in a sleeping room when the provisions for combustion, ventilation and dilution air are met per the requirements of ANSI 223.1/NFPA 54 National Fuel Gas Code. In Canada, installation in a sleeping room requires installation with a thermostat certified for use with this prod- uct. Consult your local authorities having jurisdiction.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Tempered Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

C. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

Size

(U.S. or Canada)

BTU/h

BTU/h

(DMS)

 

 

US

37,000

26,000

32

GBST4336I (NG)

 

(0-2000 FT)

 

 

 

 

GBFL4136I (NG)

 

CANADA

33,300

23,400

33

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

US

36,000

27,000

50

GBST4336I (LP)

 

(0-2000 FT)

 

 

 

 

GBFL4136I (LP)

 

CANADA

32,400

24,300

51

 

 

(2000-4500 FT)

 

 

 

 

 

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA

C22.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Heatilator • GBST4336I, GBFL4136I • 2135-900 Rev. D • 11/08

7

Image 7
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupReference Materials CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseGBFL4136I GBFL4136I Mantel Projection Mantel and Wall Projections GBST4336I Mantel ProjectionCombustible Mantel Legs or Wall Projections Fireplace OpeningVent Termination Minimum Clearances Termination LocationsModels Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationVertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingAppliance Preparation Installing Outside Air Kit Damper Assem- blyGas and Electrical Connections Proper Positioning, Leveling And Securing Securing and Leveling the ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Junction Box Detail Junction Box InstallationFinishing To install the Splatter GuardSplatter Guard To Remove the Splatter Guard To Close the Lower Access Panel12 Minimum Vertical and Maximum Horizontal GBFL4136I Pier Mantel ProjectionFacing Material 17 Noncombustible Facing DiagramAppliance Setup Models GDST4336I, GDFL4136I, GDCL4136I, GBST4336I, GBFL4136I Install the Log AssemblyModel GDCR4136I Placement of Log #2Burner Air Shutter Setting Install Trim Kits and SurroundsAir Shutter Settings Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Intellifire Ignition System Reference Materials Appliance Dimension DiagramFront View Service Parts Log Set AssemblyPart number list on following At Depot GBST4336IGBFL4136I Stocked Service Parts ListGBST4336I, GBFL4136I IPI Valve AssemblyContact Information
Related manuals
Manual 49 pages 62.21 Kb

GBST4336I, GBFL4136I specifications

Hearth and Home Technologies has made significant strides in the realm of contemporary heating solutions with their innovative products, the GBST4336I and GBFL4136I fireplace inserts. These models exemplify a blend of cutting-edge technology, aesthetic design, and user-friendly features aimed at enhancing the home heating experience.

The GBST4336I, known for its striking design and powerful performance, offers a modern solution to traditional heating methods. This model showcases a large viewing area, providing an expansive glimpse into the mesmerizing flames. Its efficient combustion system allows for exceptional heat output while minimizing emissions, making it an eco-friendly choice for homeowners. The insert is designed to fit seamlessly into most existing fireplace spaces, significantly enhancing the ambiance and warmth of any living area.

On the other hand, the GBFL4136I model is tailored for those seeking a more traditional wood-burning experience combined with modern efficiency. This insert features an impressive firebox capacity, allowing users to load more wood for longer burn times. The innovative air wash system keeps the glass clean, ensuring an unobstructed view of the fire. Additionally, the optional blower enhances heat circulation throughout the room, making it perfect for large spaces.

Both models are equipped with advanced technologies that contribute to their reliability and performance. The adjustable burn settings allow users to regulate heat output based on their specific needs, making these inserts versatile for different settings. Furthermore, they include the latest in safety features such as automatic shut-off capabilities, ensuring peace of mind while enjoying the warmth of the fire.

Aesthetically, both the GBST4336I and GBFL4136I come with customizable options, allowing homeowners to choose from various trim and finish choices to fit their home décor. The modern design elements, combined with classic fireplace features, ensure that these inserts not only heat the space but also serve as a stunning focal point in any room.

In summary, Hearth and Home Technologies' GBST4336I and GBFL4136I fireplace inserts stand out for their exceptional design, advanced technology, and practicality. They cater to the needs of modern homeowners by offering efficient heating solutions while maintaining an inviting and stylish atmosphere. With features that prioritize performance and safety, these inserts are an excellent choice for anyone looking to enhance their living space with the warmth and beauty of a fire.