Hearth and Home Technologies FL92 MULTI-SIDED Sidewalls/Surrounds, Frame the Fireplace

Page 20

C. Sidewalls/Surrounds

Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fireplace opening.

Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area, Figure 6.3.

4 in.

[102 mm]

11.92in. [303 mm]

FLUSH

FRONT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36 in.

 

 

 

 

 

 

 

angle

 

 

[914 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50°

 

 

 

 

 

 

 

 

 

 

 

(fireplace opening)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1016 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 in.

 

 

 

[305 mm]

 

 

 

 

 

 

36 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[914 mm]

 

39°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(fireplace opening

 

 

 

 

 

angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1016 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 in.

 

 

 

 

 

 

 

 

 

[305 mm]

9 3/4 in.

[248 mm]

BRICK

FRONT

Figure 6.3 Mantel Leg or Wall Projections

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).

Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

Framing across the top of fireplace must be above top standoffs.

2 in. (51 mm) Minimum Air Space Clearance to Enclosure

Mantel

12 in. (305 mm) maximum

42-1/2 in.

(1080 mm)

22-1/2 in.

(572 mm)

36 in. min.

(914 mm)

47-1/8 in. (1197 mm) header height. Use only non-combustible material below the standoffs.

Figure 6.4 Framing the Fireplace

20

Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev AA 7/12

Image 20
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsNumber Model Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Limited Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyWarranty Conditions This warranty is void ifListing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Maintenance and Service Chimney Inspection/CleaningDisposal of Ashes Creosote Formation and Need for RemovalGlass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Air Space ClearancesSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Install Outside Air Kit AK14/AK18 InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmComplete Installation Install FlashingFollowing steps should be skipped if using a chase Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175 Square Termination CapTCT1175 Terra Cotta Cap Shrouds Radiation ShieldField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Hearth Extension Dimensions Finishing Material Hearth Refractory In. Micore or equivilent insulationCombustible Mantel SealantAccessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.113 mm Fireplace DimensionsReference Materials Chimney Components Catalog # Description15-1/4 387 mm 25-1/4 737 mm 641 mm 483 mm 15-5/8 397 mm Multi-Sided Woodburning Fireplace Service PartsPart numbers on following At Depot StockedContact Information

FL92 MULTI-SIDED specifications

The Hearth and Home Technologies FL92 MULTI-SIDED fireplace stands out as a versatile and stylish option for modern living spaces. This innovative fireplace offers impressive functionality, blending warmth and ambiance with contemporary design. One of its main features is its multi-sided configuration, which allows for a unique installation that can transform any room. With options for both three-sided and two-sided designs, it facilitates an open, spacious feel and encourages a flow of light and warmth across multiple areas.

The FL92 MULTI-SIDED is built with advanced technology that enhances both performance and user experience. It features a powerful heat exchanger system that efficiently distributes warmth throughout the room, making it an excellent choice for heating larger areas. Additionally, its adaptive ignition ensures an efficient burn, minimizing energy consumption while maximizing output. This eco-friendly approach not only benefits homeowners but also the environment by reducing emissions.

The design of the FL92 MULTI-SIDED is equally impressive. It boasts a sleek, contemporary appearance that can seamlessly integrate into various interior styles, from modern to rustic. The expansive glass viewing area provides an unobstructed view of the mesmerizing flames, creating a focal point in any setting. Customizable trim options and finishes allow homeowners to tailor the fireplace to their specific aesthetic preferences, ensuring it complements their decor beautifully.

One of the standout characteristics of the FL92 MULTI-SIDED is its ease of operation. The fireplace can be controlled via a remote, offering convenience for users when managing heat and flame height. Moreover, it includes a self-diagnostic control system that aids in monitoring the fireplace's performance, ensuring safety and efficiency over time.

Whether used as a primary heating source or a visual centerpiece, the Hearth and Home Technologies FL92 MULTI-SIDED fireplace offers an impressive combination of style, functionality, and innovative technology. Its multi-sided design, efficient heating capabilities, eco-friendly operation, and aesthetic versatility make it an exceptional choice for homeowners looking to enhance their living spaces with the warmth and charm of a contemporary fireplace.