Hearth and Home Technologies FL92 MULTI-SIDED Installation of Fireplace, Things to Consider

Page 21

7Installation of Fireplace

Caution! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.

A. Things to Consider

Location of chimney air kit inlet (see Figure 5.1 & 7.4)

Location of outside air kit

Electrical connections and/or wall switch

Gas line piping

B. Position the Fireplace

Place the fireplace on a continuous flat surface.

Follow framing instructions in Section 6.

Warning! Risk of Fire! Prevent contact with sag- ging, loose insulation.

DO NOT install against vapor barriers or exposed insulation.

Secure insulation and vapor barriers.

Provide minimum air space clearances at the sides and back of the fireplace assembly as outlined in Section 6.

C. Place Protective Metal Hearth Strips

Warning! Risk of Fire! Protective metal hearth strips MUST be installed. DO NOT cover metal strips with com- bustible materials. Sparks or embers may ignite flooring.

Refer to Figures 7.1 and 7.2.

Locate the two protective metal hearth strips measuring approximately 26 in. x 4 in. (660 mm x 102 mm) included with this fireplace.

Slide each metal strip 2 in. (51 mm) under front edge of fireplace.

Overlap strips in the middle of fireplace opening by 1 in. (25 mm) minimum..

Metal strips must extend beyond the front and sides of the fireplace opening by at least 2 in. (51 mm).

Protect the front of a platform elevated above the hearth extension with metal strips (not included with fireplace) per Figure 7.2. See Section 11 for hearth extension instructions.

D. Level Fireplace

Level fireplace side-to-side and front-to-back.

Shim with non-combustible material as necessary.

Secure fireplace to framing with nailing flanges with a minimum of two fasteners per nailing flange.

Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal.

1 in. (25 mm) overlap

Metal strips 2 in. (51 mm) under the edges of the fireplace and must extend beyond the front and side openings by 2 in. (51 mm)

Figure 7.1 Position the Protective Metal Hearth Strips

 

Top piece must overlap

 

bottom piece

 

Raised Platform

2 in.

1 in. (25 mm) min.

(51 mm)

overlap

Floor

2 in.

(51 mm)

Figure 7.2 Protect the Front of an Elevated Platform

Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev AA 7/12

21

Image 21
Contents Hot screen/mesh and glass doors will cause burns Fire RiskListing Label Information/Location GrateNumber Model Table of Contents Installer GuideUser Guide Limited Lifetime Warranty Limited Warranty Hearth & Home Technologies IncThis warranty is void if Warranty ConditionsAppliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintenance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Select Fireplace Location Framing & ClearancesAir Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet AK14/AK18 Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield requiredFinishing Hearth Extension= 1/k x inches of thickness Hearth Extension Dimensions Hearth Refractory In. Micore or equivilent insulation Finishing MaterialSealant Combustible MantelGas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference Materials13 mm Catalog # Description Chimney Components15-1/4 387 mm 25-1/4 737 mm 641 mm 483 mm 15-5/8 397 mm Service Parts Part numbers on followingMulti-Sided Woodburning Fireplace Stocked At DepotContact Information

FL92 MULTI-SIDED specifications

The Hearth and Home Technologies FL92 MULTI-SIDED fireplace stands out as a versatile and stylish option for modern living spaces. This innovative fireplace offers impressive functionality, blending warmth and ambiance with contemporary design. One of its main features is its multi-sided configuration, which allows for a unique installation that can transform any room. With options for both three-sided and two-sided designs, it facilitates an open, spacious feel and encourages a flow of light and warmth across multiple areas.

The FL92 MULTI-SIDED is built with advanced technology that enhances both performance and user experience. It features a powerful heat exchanger system that efficiently distributes warmth throughout the room, making it an excellent choice for heating larger areas. Additionally, its adaptive ignition ensures an efficient burn, minimizing energy consumption while maximizing output. This eco-friendly approach not only benefits homeowners but also the environment by reducing emissions.

The design of the FL92 MULTI-SIDED is equally impressive. It boasts a sleek, contemporary appearance that can seamlessly integrate into various interior styles, from modern to rustic. The expansive glass viewing area provides an unobstructed view of the mesmerizing flames, creating a focal point in any setting. Customizable trim options and finishes allow homeowners to tailor the fireplace to their specific aesthetic preferences, ensuring it complements their decor beautifully.

One of the standout characteristics of the FL92 MULTI-SIDED is its ease of operation. The fireplace can be controlled via a remote, offering convenience for users when managing heat and flame height. Moreover, it includes a self-diagnostic control system that aids in monitoring the fireplace's performance, ensuring safety and efficiency over time.

Whether used as a primary heating source or a visual centerpiece, the Hearth and Home Technologies FL92 MULTI-SIDED fireplace offers an impressive combination of style, functionality, and innovative technology. Its multi-sided design, efficient heating capabilities, eco-friendly operation, and aesthetic versatility make it an exceptional choice for homeowners looking to enhance their living spaces with the warmth and charm of a contemporary fireplace.