Hearth and Home Technologies EM-485T - 42 Design and Installation Considerations, Draft

Page 15

B. Design and Installation Considerations

NOTICE: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the fireplace is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch or remote control—are desired.

C. Draft

Draft is the pressure difference needed to vent fireplaces successfully. When a fireplace is drafting successfully, all combustion byproducts are exiting the home through the chimney.

Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

NOTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by:

Inadequate draft due to environmental conditions

Downdrafts

Tight sealing construction of the structure

Mechanical exhausting devices

Improper location of the chimney

D. Negative Pressure

WARNING! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. It can be stron- gest in lower levels of the house.

Causes include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:

-Recessed lighting

-Attic hatch

-Duct leaks

To minimize the effects of negative air pressure:

Install the outside air kit with the intake facing prevailing winds during the heating season

Ensure adequate outdoor air for all combustion appliances and exhaust equipment

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace

Avoid installing the fireplace near doors, walkways or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and seams taped or sealed

Basement installations should be avoided

NOTICE: Hearth & Home Technologies Inc. recommends the use of direct vent fireplaces in basements.

Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08

15

Image 15
Contents Fire Risk Wood Burning FireplaceOperation Hot screen/mesh and glass doors will cause burnsListing Label Information/Location GrateNumber User Guide Table of ContentsInstaller Guide Safety Alert KeyCONDITIONS, Exclusions & Limitation of Liability ¨ Hearth & Home Technologies Limited WarrantyHeat & Glo EM-415, EM-485 33056 Rev W 10/08 Combustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Firescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelMaintainance and Service Chimney Inspection/CleaningDisposal of Ashes Frequency As desired Glass CleaningCheck Firebox Refractory Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededSelect Fireplace Location Fireplace Dimensions .A 1219 mm MinimumMm all configurations Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceFt min. from top of uppermost chimney section to air inlet Secure flex duct with metal tape, screws or wire ties Install Outside Air KitJunction Box Installation Hood Wire TiesPrepare Junction Box Bracket Installation of FanMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsInstall Chimney Air Kit Installing Ceiling FirestopsAssembling Chimney Sections Prepare Attic Insulation Shield Installing Attic Insulation ShieldComplete Installation Install FlashingCut out Hole in Roof Flat Roofs Chimney Termination RequirementsChase should be constructed in the manner of all Chase InstallationsConstruct the Chase Gas line holes and other openings should be caulked withInstall Chase Top Install Fireplace & ChimneyST375 Square Termination Cap Install Termination CapTS345/TS345P Square Termination Cap European Copper Series Termination CapTCT375 Terra Cotta Cap Field Constructed Shrouds Some shrouds require a radiation shield. Use where specifiedShrouds Radiation ShieldMailbox Style Shroud radiation shield required Finishing Hearth Extension= 1/k x inches of thickness Noncombustible Facing Finishing Material305 mm Combustible MantelWood Burning Inserts AccessoriesInstall Fan Gas Log/Lighter ProvisionAir 594 mm 92 mmGas Knockout Outside 23-3/8Catalog # Description Fireplace Components13 mm 1676 mm 508 mmCatalog # Chimney Components305 mm 24-5/8 625 mm 787 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm10-1/2 267 mm 305 mm 27-3/8 24-5/8 695 mm 625 mmTR-TVK CT-3A 10-7/8 276 mm EM-415 Service PartsEM-485T This page intentionally left blank Do not Discard this Manual

EM-485T - 42, EM-415 - 36 specifications

Hearth and Home Technologies has long been a leader in the fireplace and heating solutions industry, and among their latest offerings is the EM-415 - 36 and EM-485T - 42 models. These elegant units blend aesthetics with advanced technology, making them a perfect addition to any modern home.

The EM-415 - 36 model features a 36-inch viewing area, offering an expansive flame look that enhances any room's ambiance. On the other hand, the EM-485T - 42 boasts a larger 42-inch viewing area, providing an even more impressive visual display. Both designs prioritize an open front that allows for maximum natural light while showcasing the fire's beauty.

One of the main features of both models is their efficiency. They utilize advanced venting systems that allow for a balanced flow of air and smoke, ensuring that the fire burns cleanly and efficiently. This not only contributes to a reduced environmental impact but also helps to lower energy costs for homeowners. The EM-415 and EM-485T are designed to meet or exceed various efficiency standards, making them a responsible choice for homeowners concerned about energy use.

In terms of heat output, both models are equipped with powerful burners that provide ample warmth for larger spaces. With adjustable flame settings, users can customize their experience to either enjoy a cozy fire during colder months or opt for a gentle warmth that’s suitable for entertaining during milder weather.

The aesthetic design of the EM-415 and EM-485T is another notable feature. They come with various customizable options, including different finishes and decorative media, allowing homeowners to tailor the appearance to their personal style and home decor. The clean, contemporary aesthetic ensures that these fireplaces are not just functional, but also a centerpiece of elegance in any room.

Installation is made convenient thanks to the thoughtfully designed systems in both models. They can be installed easily in a variety of settings, including new constructions and renovations. The straightforward operation and maintenance further ensure that homeowners will enjoy these fireplaces hassle-free.

Safety is also paramount with Hearth and Home Technologies. The EM-415 and EM-485T units are fitted with advanced safety mechanisms, such as automatic shut-off features and protective screens, ensuring peace of mind for users and their families.

In conclusion, the Hearth and Home Technologies EM-415 - 36 and EM-485T - 42 models combine striking aesthetics with advanced technology and efficiency. Their innovative features and safety measures make them appealing options for those looking to elevate their living space while enjoying the warmth and ambiance of a beautiful fire.