NOTICE: Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.

Chimney must extend beyond combustible roof structure

Maintain minimum height of chimney above roof

Install roof flashing according to minimum requirements

Offsets/returns may not exceed 30° from vertical

Lock chimney sections together firmly to resist movement

Termination Cap

Additional support for tall chimneys

Storm Collar

Maintain minimum clearances to combustibles as specified

Support straps for returns must be secured to adequate framing

Offsets and returns must be secured with the screws provided (outer pipe only)

Ceiling firestops are required where chimney passes through ceiling or floor

Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation

Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08

25

Image 25
Contents Operation Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Fire RiskGrate Listing Label Information/LocationNumber Installer Guide Table of ContentsSafety Alert Key User GuideCONDITIONS, Exclusions & Limitation of Liability ¨ Hearth & Home Technologies Limited WarrantyHeat & Glo EM-415, EM-485 33056 Rev W 10/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceHardwood vs Softwood Wood FuelChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDraft Design and Installation ConsiderationsNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededMm all configurations Fireplace Dimensions .A 1219 mm MinimumFraming & Clearances Select Fireplace LocationClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Junction Box Installation Install Outside Air KitHood Wire Ties Secure flex duct with metal tape, screws or wire tiesPrepare Junction Box Bracket Installation of FanMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsInstalling Ceiling Firestops Install Chimney Air KitAssembling Chimney Sections Prepare Attic Insulation Shield Installing Attic Insulation ShieldInstall Flashing Complete InstallationCut out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsGas line holes and other openings should be caulked with Chase should be constructed in the manner of allInstall Chase Top Install Fireplace & ChimneyST375 Square Termination Cap Install Termination CapEuropean Copper Series Termination Cap TS345/TS345P Square Termination CapTCT375 Terra Cotta Cap Shrouds Some shrouds require a radiation shield. Use where specifiedRadiation Shield Field Constructed ShroudsMailbox Style Shroud radiation shield required Hearth Extension Finishing= 1/k x inches of thickness Noncombustible Facing Finishing Material305 mm Combustible MantelInstall Fan AccessoriesGas Log/Lighter Provision Wood Burning InsertsGas Knockout 92 mmOutside 23-3/8 Air 594 mmCatalog # Description Fireplace Components13 mm 1676 mm 508 mmCatalog # Chimney Components10-1/2 267 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mmTR-TVK CT-3A 10-7/8 276 mm EM-415 Service PartsEM-485T This page intentionally left blank Do not Discard this Manual

EM-485T - 42, EM-415 - 36 specifications

Hearth and Home Technologies has long been a leader in the fireplace and heating solutions industry, and among their latest offerings is the EM-415 - 36 and EM-485T - 42 models. These elegant units blend aesthetics with advanced technology, making them a perfect addition to any modern home.

The EM-415 - 36 model features a 36-inch viewing area, offering an expansive flame look that enhances any room's ambiance. On the other hand, the EM-485T - 42 boasts a larger 42-inch viewing area, providing an even more impressive visual display. Both designs prioritize an open front that allows for maximum natural light while showcasing the fire's beauty.

One of the main features of both models is their efficiency. They utilize advanced venting systems that allow for a balanced flow of air and smoke, ensuring that the fire burns cleanly and efficiently. This not only contributes to a reduced environmental impact but also helps to lower energy costs for homeowners. The EM-415 and EM-485T are designed to meet or exceed various efficiency standards, making them a responsible choice for homeowners concerned about energy use.

In terms of heat output, both models are equipped with powerful burners that provide ample warmth for larger spaces. With adjustable flame settings, users can customize their experience to either enjoy a cozy fire during colder months or opt for a gentle warmth that’s suitable for entertaining during milder weather.

The aesthetic design of the EM-415 and EM-485T is another notable feature. They come with various customizable options, including different finishes and decorative media, allowing homeowners to tailor the appearance to their personal style and home decor. The clean, contemporary aesthetic ensures that these fireplaces are not just functional, but also a centerpiece of elegance in any room.

Installation is made convenient thanks to the thoughtfully designed systems in both models. They can be installed easily in a variety of settings, including new constructions and renovations. The straightforward operation and maintenance further ensure that homeowners will enjoy these fireplaces hassle-free.

Safety is also paramount with Hearth and Home Technologies. The EM-415 and EM-485T units are fitted with advanced safety mechanisms, such as automatic shut-off features and protective screens, ensuring peace of mind for users and their families.

In conclusion, the Hearth and Home Technologies EM-415 - 36 and EM-485T - 42 models combine striking aesthetics with advanced technology and efficiency. Their innovative features and safety measures make them appealing options for those looking to elevate their living space while enjoying the warmth and ambiance of a beautiful fire.