Hearth and Home Technologies EM-415 - 36 Assembling Chimney Sections, Install Chimney Air Kit

Page 28

C. Assembling Chimney Sections

WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components.

Use only those components described in this manual.

Substitute or damaged chimney components could impair safe operation and cause overheating and fire.

Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

Attach a straight chimney section or an offset to the top of the fireplace.

Place inner flue to the inside of the chimney section below it. Place the outer casing outside the outer casing of the chimney section below it. Refer to Figure 8.4.

NOTICE: Chimney sections cannot be disassembled once locked together. Plan ahead!

Lock chimney sections and/or offsets/returns together by pushing downward until the top section meets the stop bead on the lower section.

Pull on the top section to make sure it is fully engaged and will not separate.

You may use #6 or #8 sheet metal screws no longer than 1/2 in. (13 mm) to fasten chimney sections together. Do not penetrate inner flue.

WARNING! Risk of Fire! You MUST use screws (pro- vided) to fasten offset/returns to chimney sections to keep the chimney parts from twisting. Failure to do so could cause fire.

Fasten offset/returns to chimney sections. Insert the screws (provided) through the predrilled holes. Do not penetrate inner flue.

Secure chimney returns with hanger straps provided; fasten to studs or joists.

Vertical straight runs of chimney must be supported every 35 ft (10.7 m).

Figure 8.4 Assembling Chimney Sections

D. Install Chimney Air Kit

Required in Canada.

Follow instructions provided with this accessory.

E. Installing Ceiling Firestops

CAUTION! Risk of Fire! Ceiling firestops must be used whenever the chimney penetrates a ceiling/floor.

Chase construction requires ceiling firestops at each floor or every 10 ft (3.05 m) of clear space.

The ceiling firestop slows spread of fire and reduc- es cold air infiltration.

Install a ceiling firestop whenever chimney penetrates ceiling/floor.

Mark and cut an opening in ceiling as shown in Figure 8.5.

Frame the opening with the same size lumber used in the ceiling joists.

Nail the ceiling firestop to the bottom of the ceiling joists when there is a room above.

Use an attic insulation shield if the ceiling is insulated. The ceiling firestop may then be attached above or below the joists.

WARNING! Risk of Fire! DO NOT seal area between firestop opening and chimney pipe. Restricting air flow around chimney may cause fire.

ROOM ABOVE (non-insulated ceiling)

B

A

Ceilng firestop from

bottom

ATTIC ABOVE (insulated ceiling)

Ceiling firestop from

top

Note: Use same dimensional lumber for framing ceiling firestop and joists.

 

 

A

 

B

 

Catalog #

in.

 

mm

in.

 

mm

Angle

FS338

14-1/2

 

368

14-1/2

 

368

FS339

14-1/2

 

368

18-3/8

 

467

15°

 

 

 

 

 

 

 

 

FS340

14-1/2

 

368

23

 

584

30°

Figure 8.5 Installing the Ceiling Firestop

28

Heat & Glo • EM-415, EM-485 • 33056 • Rev W • 10/08

Image 28
Contents Wood Burning Fireplace OperationHot screen/mesh and glass doors will cause burns Fire RiskGrate Listing Label Information/LocationNumber Table of Contents Installer GuideSafety Alert Key User Guide¨ Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeat & Glo EM-415, EM-485 33056 Rev W 10/08 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Seasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Hardwood vs SoftwoodChimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Glass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDraft Design and Installation ConsiderationsNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsTools and Supplies Needed Inspect Fireplace and ComponentsFireplace Dimensions .A 1219 mm Minimum Mm all configurationsFraming & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Install Outside Air Kit Junction Box InstallationHood Wire Ties Secure flex duct with metal tape, screws or wire tiesInstallation of Fan Prepare Junction Box BracketChimney Assembly Maintain minimum height of chimney above roofChimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstalling Ceiling Firestops Install Chimney Air KitAssembling Chimney Sections Installing Attic Insulation Shield Prepare Attic Insulation ShieldInstall Flashing Complete InstallationCut out Hole in Roof Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseGas line holes and other openings should be caulked with Chase should be constructed in the manner of allInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST375 Square Termination CapEuropean Copper Series Termination Cap TS345/TS345P Square Termination CapTCT375 Terra Cotta Cap Some shrouds require a radiation shield. Use where specified ShroudsRadiation Shield Field Constructed ShroudsMailbox Style Shroud radiation shield required Hearth Extension Finishing= 1/k x inches of thickness Finishing Material Noncombustible FacingCombustible Mantel 305 mmAccessories Install FanGas Log/Lighter Provision Wood Burning Inserts92 mm Gas KnockoutOutside 23-3/8 Air 594 mmFireplace Components Catalog # Description1676 mm 508 mm 13 mmChimney Components Catalog #Effective Outside Height Diameter 10-1/2 121 mm 267 mm 10-1/2 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mmTR-TVK CT-3A 10-7/8 276 mm Service Parts EM-415EM-485T This page intentionally left blank Do not Discard this Manual

EM-485T - 42, EM-415 - 36 specifications

Hearth and Home Technologies has long been a leader in the fireplace and heating solutions industry, and among their latest offerings is the EM-415 - 36 and EM-485T - 42 models. These elegant units blend aesthetics with advanced technology, making them a perfect addition to any modern home.

The EM-415 - 36 model features a 36-inch viewing area, offering an expansive flame look that enhances any room's ambiance. On the other hand, the EM-485T - 42 boasts a larger 42-inch viewing area, providing an even more impressive visual display. Both designs prioritize an open front that allows for maximum natural light while showcasing the fire's beauty.

One of the main features of both models is their efficiency. They utilize advanced venting systems that allow for a balanced flow of air and smoke, ensuring that the fire burns cleanly and efficiently. This not only contributes to a reduced environmental impact but also helps to lower energy costs for homeowners. The EM-415 and EM-485T are designed to meet or exceed various efficiency standards, making them a responsible choice for homeowners concerned about energy use.

In terms of heat output, both models are equipped with powerful burners that provide ample warmth for larger spaces. With adjustable flame settings, users can customize their experience to either enjoy a cozy fire during colder months or opt for a gentle warmth that’s suitable for entertaining during milder weather.

The aesthetic design of the EM-415 and EM-485T is another notable feature. They come with various customizable options, including different finishes and decorative media, allowing homeowners to tailor the appearance to their personal style and home decor. The clean, contemporary aesthetic ensures that these fireplaces are not just functional, but also a centerpiece of elegance in any room.

Installation is made convenient thanks to the thoughtfully designed systems in both models. They can be installed easily in a variety of settings, including new constructions and renovations. The straightforward operation and maintenance further ensure that homeowners will enjoy these fireplaces hassle-free.

Safety is also paramount with Hearth and Home Technologies. The EM-415 and EM-485T units are fitted with advanced safety mechanisms, such as automatic shut-off features and protective screens, ensuring peace of mind for users and their families.

In conclusion, the Hearth and Home Technologies EM-415 - 36 and EM-485T - 42 models combine striking aesthetics with advanced technology and efficiency. Their innovative features and safety measures make them appealing options for those looking to elevate their living space while enjoying the warmth and ambiance of a beautiful fire.