Hearth and Home Technologies Cyclone-BC, Cyclone-BN Vent Information and Diagrams, Vent Table Key

Page 12

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

B. Use of Elbows

CAUTION

ALL vent configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Diagonal runs have both vertical and horizontal vent as- pects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 5.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8-1/2 (216 mm) inches horizontal run and 8-1/2 (216 mm) inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 5.1).

Verticalin. 1/2-8

8-1/2 in.

Horizontal

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

Pipe measurements are shown using the effective length of pipe (see Figure 5.2).

Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 4.1).

Vertical terminations are measured to bottom of termi- nation cap.

Horizontal pipe installed level with no rise.

 

Effective Height/Length

 

Pipe

inches

mm

 

SLP4

4

102

Effective

SLP6

6

152

SLP12

12

305

Height/

SLP24

24

610

Length

 

SLP36

36

914

 

SLP48

48

1219

 

SLP6A

2 - 6

51 - 152

 

SLP12A

2 - 12

51 - 305

Figure 5.2 SLP Pipe Effective Length

12

Heat & Glo • Cyclone-BN, Cyclone-BC2073-900 Rev. N • 10/08

Image 12
Contents Model Cyclone-BN Cyclone-BC What to do if you smell gasHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationModel Constructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Min MaxTop Vent Horizontal Termination Three Elbows Top Vent Vertical Termination No Elbow Flex VentTop Vent Vertical Termination Two Elbows Three Elbows Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Installing Exhaust Baffle Appliance PreparationSecuring and Leveling the Appliance Installing Vent Pipe Assemble Vent SectionsAssemble Slip Sections Secure the Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 Apply Sealant TOP & Partial SidesInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 22 Venting through the wallGas Information Fuel ConversionsGas Pressures Gas ConnectionHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Hot Surface Ignition Wiring Optional Accessories RequirementsFinishing Facing MaterialAppliance Setup Remove Shipping Materials Glass Assembly InstallationClean the Appliance AccessoriesRemote Control Service Operating Instructions Before Lighting ApplianceTurn off all electric power to the appliance Lighting Instructions IPIFinal inspection by Frequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Fan Motor Service Maintaining and Servicing ApplianceSide Reflector Panel Installation Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeter Vent Components Diagrams ElbowRF4-8 Roof Flashing Ceiling FirestopSupport Box-Black AdapterBlack Service Parts StockedAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-BN, Cyclone-BC specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its Cyclone series, which includes the Cyclone-BC and Cyclone-BN models. These wood-burning fireplaces are engineered with cutting-edge technologies that ensure efficient and environmentally friendly heating, making them popular choices for homeowners seeking both functionality and aesthetics.

One of the standout features of the Cyclone series is its innovative air wash system. This technology works to keep the glass panel clean by directing a stream of pre-heated air along the inside surface, effectively reducing the accumulation of soot and ash. As a result, users can enjoy a clear view of the mesmerizing flames without the hassle of constant cleaning.

In terms of efficiency, the Cyclone-BC and Cyclone-BN models boast an exceptional thermal efficiency rating. Thanks to their advanced combustion technology, these fireplaces burn wood more completely, resulting in less smoke and harmful emissions. The high-efficiency design not only benefits the environment but also ensures that heat is maximized, helping to lower heating costs for homeowners.

The construction of the Cyclone fireplaces is another highlight. Built with high-quality materials, these units are designed to withstand the rigors of daily use and maintain their performance over time. Their robust firebox is engineered to accommodate larger logs, offering longer burn times and fewer reloads.

Both models are highly versatile in their aesthetic appeal. The Cyclone-BC features a classic, traditional design that fits seamlessly into a variety of home decors, while the Cyclone-BN leans toward a more contemporary style. Homeowners can customize the look even further with different finishing options, allowing for a personalized touch that complements their unique interior settings.

Safety is paramount in the design of the Cyclone series. These fireplaces come equipped with advanced safety features, including a protective screen and secure door latch, providing peace of mind for families. Additionally, the heat output can be easily controlled, allowing users to adjust the flame and temperature to their desired comfort level.

In conclusion, Hearth and Home Technologies’ Cyclone-BC and Cyclone-BN fireplaces deliver on both performance and style. With efficient heating capabilities, innovative technologies, and a range of design options, these wood-burning units are an exceptional choice for those looking to enhance their living space while enjoying the warmth and ambiance that only a real fire can provide.